Para acceder a los documentos con el texto completo, por favor, siga el siguiente enlace: http://hdl.handle.net/2117/27493
Título:
|
Low-cost method to estimate body capacitance to ground at mid frequencies
|
Autor/a:
|
Aliau Bonet, Carles; Pallàs Areny, Ramon
|
Otros autores:
|
Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica; Universitat Politècnica de Catalunya. GRUP ISI - Grup d'Instrumentació, Sensors i Interfícies |
Abstract:
|
Impedance measurements that involve the human body are affected by the capacitance between the body and earth ground. This paper describes a low-cost method to estimate that capacitance that can be applied to impedance analyzers intended to measure ungrounded impedances and also to inexpensive handheld LCR meters. The method does not require any external component other than two common capacitors and two electrodes in contact with the body. |
Materia(s):
|
-Àrees temàtiques de la UPC::Enginyeria electrònica -Impedance (Electricity) -Human body capacitance -parasitic capacitance -measurement error -Impedància (Electricitat) |
Derechos:
|
|
Tipo de documento:
|
Artículo - Versión publicada Objeto de conferencia |
Compartir:
|
|
Mostrar el registro completo del ítem