Title:
|
Real time 100 GHz MST imaging retina
|
Author:
|
Alonso del Pino, María; Garg, V.; García Guerra, Carlos Enrique; Romeu Robert, Jordi; Llombart, Nuria; Jofre Roca, Lluís
|
Other authors:
|
Universitat Politècnica de Catalunya. Departament de Teoria del Senyal i Comunicacions; Universitat Politècnica de Catalunya. ANTENNALAB - Grup d'Antenes i Sistemes Radio |
Abstract:
|
A real time tomographic imaging system at 100 GHz based on a retina and Modulated Scattered Technique (MST) is presented in this paper. It consists in applying a low frequency modulation to each probe of an array of antennas in order to coherently detect the electric field by a collector. This system just requires low frequency wiring and reduces the RF equipment necessary for each pixel for a planar surface. The aim of this paper is to analyze the performance of different tomographic imaging processes for the imaging system described. |
Abstract:
|
Peer Reviewed |
Subject(s):
|
-Àrees temàtiques de la UPC::Enginyeria de la telecomunicació::Radiocomunicació i exploració electromagnètica::Antenes i agrupacions d'antenes -Àrees temàtiques de la UPC::Enginyeria electrònica::Optoelectrònica -Tomography -Antennas (Electronics) -antenna design -imaging reconstruction -imaging system -MST -Real time -Retina -THz -tomography -Antenes (Electrònica) -Tomografia |
Rights:
|
|
Document type:
|
Article - Published version Conference Object |
Published by:
|
Institute of Electrical and Electronics Engineers (IEEE)
|
Share:
|
|