Título:
|
Comparison of demand calibration in water distribution networks using pressure and flow sensors
|
Autor/a:
|
Sanz Estapé, Gerard; Pérez Magrané, Ramon
|
Otros autores:
|
Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial; Universitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control |
Abstract:
|
Water distribution network models are used by water companies in a wide range of applications. A good calibration of these models is required in order to improve the confidence of the application results. Pressure and flow measurements are the main source of information when calibrating a hydraulic model. The selection of both the type and location of the sensors is crucial to guarantee a good calibration. This paper describes a sensor placement methodology based on the analysis of pressure and flow sensitivity using the Singular Value Decomposition. A comparison of demand calibration in a real network with synthetic data is presented. Three sets of sensors are considered: pressure sensors, flow sensors, and a combination of both. |
Abstract:
|
Peer Reviewed |
Materia(s):
|
-Àrees temàtiques de la UPC::Informàtica::Automàtica i control -Water-supply engineering -- Computer simulation -Water distribution network models -Water Distribution Networks -Demands -Calibration -Sensors -Aigua--Abastament--Tècnica -Aigua potable -- Abastament -- Control automàtic |
Derechos:
|
|
Tipo de documento:
|
Artículo - Versión presentada Objeto de conferencia |
Compartir:
|
|