Per accedir als documents amb el text complet, si us plau, seguiu el següent enllaç: http://hdl.handle.net/2117/129544
Títol: | Surface mechanomyography and electromyography provide non-invasive indices of inspiratory muscle force and activation in healthy subjects |
---|---|
Autor/a: | Lozano, Manuel; Sarlabous Uranga, Leonardo; Moxham, John; Rafferty, Gerrard F.; Torres Cebrián, Abel; Jané Campos, Raimon; Jolley, J |
Altres autors: | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial; Universitat Politècnica de Catalunya. BIOSPIN - Biomedical Signal Processing and Interpretation |
Abstract: | The current gold standard assessment of human inspiratory muscle function involves using invasive measures of transdiaphragmatic pressure (Pdi) or crural diaphragm electromyography (oesEMGdi). Mechanomyography is a non-invasive measure of muscle vibration associated with muscle contraction. Surface electromyogram and mechanomyogram, recorded transcutaneously using sensors placed over the lower intercostal spaces (sEMGlic and sMMGlic respectively), have been proposed to provide non-invasive indices of inspiratory muscle activation, but have not been directly compared to gold standard Pdi and oesEMGdi measures during voluntary respiratory manoeuvres. To validate the non-invasive techniques, the relationships between Pdi and sMMGlic, and between oesEMGdi and sEMGlic were measured simultaneously in 12 healthy subjects during an incremental inspiratory threshold loading protocol. Myographic signals were analysed using fixed sample entropy (fSampEn), which is less influenced by cardiac artefacts than conventional root mean square. Strong correlations were observed between: mean Pdi and mean fSampEn |sMMGlic| (left, 0.76; right, 0.81), the time-integrals of the Pdi and fSampEn |sMMGlic| (left, 0.78; right, 0.83), and mean fSampEn oesEMGdi and mean fSampEn sEMGlic (left, 0.84; right, 0.83). These findings suggest that sMMGlic and sEMGlic could provide useful non-invasive alternatives to Pdi and oesEMGdi for the assessment of inspiratory muscle function in health and disease. |
Abstract: | Peer Reviewed |
Matèries: | -Àrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica -Bioengineering -Bioenginyeria |
Drets: | Attribution-NonCommercial-NoDerivs 3.0 Spain
http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
Tipus de document: | Article - Versió publicada Article |
Publicat per: | Nature |
Compartir: |