Title:
|
Is it better to use gate opening as control variable than discharge to control irrigation canals?
|
Author:
|
Horváth, Klaudia; Galvis Restrepo, Eduard; Gómez Valentín, Manuel; Rodellar Benedé, José
|
Other authors:
|
Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental; Universitat Politècnica de Catalunya. Departament de Matemàtiques; Universitat Politècnica de Catalunya. FLUMEN - Dinàmica Fluvial i Enginyeria Hidrològica; Universitat Politècnica de Catalunya. CoDAlab - Control, Modelització, Identificació i Aplicacions |
Abstract:
|
Centralized model predictive controllers are common in water systems. The control action variable can be the discharge, and the subsystems (canal pools) are modeled separately. This paper focuses on short canal pools where the interactions are stronger between canal pools. Could this procedure be better if gate openings were used as control action variables and the interconnected system were modeled for the controller? Model predictive controllers (MPCs) were developed using the discharge and the gate opening as control action variable and tested experimentally using the laboratory canal of the Technical University of Catalonia. It was found that for centralized MPCs for short canal pools, the use of gate opening as control action variable is more beneficial than discharge. Another additional advantage is that in this way it is possible to put constraints on the gate opening and the change of gate opening, which are important to the limitations of the physical system. (C) 2014 American Society of Civil Engineers. |
Abstract:
|
Peer Reviewed |
Subject(s):
|
-Àrees temàtiques de la UPC::Enginyeria civil::Enginyeria hidràulica, marítima i sanitària::Canals i regadius -Irrigation canals and flumes--Management -Canal -Open channel -Irrigation -Active control -Feedback control -Gates -Automation -Resonance -Regatge -- Control |
Rights:
|
|
Document type:
|
Article - Submitted version Article |
Share:
|
|