Direct determination of free metal concentration by implementing stripping chronopotentiometry as second stage of AGNES

dc.contributor.author
Parat, C.
dc.contributor.author
Authier, L.
dc.contributor.author
Aguilar, David
dc.contributor.author
Companys Ferran, Encarnació
dc.contributor.author
Puy Llorens, Jaume
dc.contributor.author
Galceran i Nogués, Josep
dc.contributor.author
Potin-Gautier, M.
dc.date.accessioned
2024-12-05T22:35:34Z
dc.date.available
2024-12-05T22:35:34Z
dc.date.issued
2015-11-10T09:22:53Z
dc.date.issued
2015-11-10T09:22:53Z
dc.date.issued
2011
dc.date.issued
2015-11-10T09:22:53Z
dc.identifier
https://doi.org/10.1039/C1AN15481H
dc.identifier
0003-2654
dc.identifier
http://hdl.handle.net/10459.1/48937
dc.identifier.uri
http://hdl.handle.net/10459.1/48937
dc.description.abstract
The electroanalytical technique Absence of Gradients and Nernstian Equilibrium Stripping (AGNES) has been extended by applying stripping chronopotentiometry (SCP) as the re-oxidation stage in the determination of the free concentration of Zn2+, Cd2+ and Pb2+. This new approach, called AGNES-SCP, has been implemented with screen-printed electrodes (SPE) and the standard Hanging Mercury Drop Electrode (HMDE). Clear advantages of this variant have been shown: (i) the easy resolution of the peaks of different metals present in mixtures and (ii) the sparing of blanks. A rigorous computation of the faradaic charge along the SCP stage takes into account the contribution of other oxidants, which can be efficiently measured at the end of the deposition stage of AGNES. The free Cd concentration determined in an oxalate solution at pH 6 with an HMDE as the working electrode agreed well with values obtained with a Cd Ion Selective Electrode. The free metal concentration measured using an SPE for the system Cd and nitrilotriacetic acid (NTA) at pH = 4.8 also conformed well with Visual MINTEQ results.
dc.format
application/pdf
dc.language
eng
dc.publisher
The Royal society of Chemistry
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1039/C1AN15481H
dc.relation
Analyst, 2011, vol. 136, num. 20, p. 4337-4343
dc.rights
(c) The Royal society of Chemistry, 2011
dc.rights
info:eu-repo/semantics/openAccess
dc.subject
Metalls
dc.subject
Anàlisi electroquímica
dc.subject
Metals
dc.subject
Electrochemical analysis
dc.title
Direct determination of free metal concentration by implementing stripping chronopotentiometry as second stage of AGNES
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)