Molten salt facilities, lessons learnt at pilot plant scale to guarantee commercial plants; heat losses evaluation and correction

dc.contributor.author
Prieto, Cristina
dc.contributor.author
Osuna, Rafael
dc.contributor.author
Fernández Renna, Ana Inés
dc.contributor.author
Cabeza, Luisa F.
dc.date.accessioned
2024-12-05T22:41:18Z
dc.date.available
2024-12-05T22:41:18Z
dc.date.issued
2016-10-05T10:42:58Z
dc.date.issued
2018-08-01T22:17:33Z
dc.date.issued
2016-08
dc.date.issued
2016-10-05T10:43:03Z
dc.identifier
https://doi.org/10.1016/j.renene.2016.03.039
dc.identifier
0960-1481
dc.identifier
http://hdl.handle.net/10459.1/57867
dc.identifier.uri
http://hdl.handle.net/10459.1/57867
dc.description.abstract
This paper presents the importance of the thermal losses in the performance evaluation of thermal storage systems. In order to reinforce this statement, an evaluation of a pilot plant whose size is sufficiently representative for the extrapolation of results at larger scales has been carried out. The evaluation of the heat losses of a molten salt pilot plant with 8.1 MWhth built in Spain by Abengoa is presented. While the storage materials development has attracted a lot of attention from the researchers, the performance of a two-tank storage system has not been evaluated in detail. The relevance of the design of conventional systems such as insulation, mechanical assembly or foundation, are found to be the key for the feasibility of a TES system. Different performance scenarios were performed and based on experimental results, decisions for reengineering of the pilot plant could be taken to improve commercial storage plants.
dc.description.abstract
The research leading to these results has received funding from Spanish goverment (Fondo tecnológicoIDI-20090393, ConSOLida CENIT 2008-1005). The work is partially funded by the Spanish government (ENE2011-28269-C03-02, ENE2011-22722). The authors would like to thank the Catalan Government for the quality accreditation given to their research group GREA (2014 SGR 123) and research group DIOPMA (2014 SGR 1543).
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier
dc.relation
MICINN/PN2008-2011/ENE2011-28269-C03-02
dc.relation
MICINN/PN2008-2011/ENE2011-22722
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1016/j.renene.2016.03.039
dc.relation
Renewable Energy, 2016, vol. 94, p. 175-185
dc.rights
cc-by-nc-nd, (c) Elsevier, 2016
dc.rights
info:eu-repo/semantics/openAccess
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject
Energia tèrmica solar
dc.subject
Centrals solars
dc.subject
Solar thermal energy
dc.subject
Solar power plants
dc.title
Molten salt facilities, lessons learnt at pilot plant scale to guarantee commercial plants; heat losses evaluation and correction
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)