A radiographic measurement of left atrial size in dogs

dc.contributor.author
Sánchez Salguero, Xavier
dc.contributor.author
Prandi, David
dc.contributor.author
Llabrés-Díaz, Francisco
dc.contributor.author
Garcia Manzanilla, Edgar
dc.contributor.author
Bussadori, Claudio
dc.date.accessioned
2024-12-05T22:21:58Z
dc.date.available
2024-12-05T22:21:58Z
dc.date.issued
2019-01-21T13:08:10Z
dc.date.issued
2019-01-21T13:08:10Z
dc.date.issued
2018-12-17
dc.date.issued
2019-01-21T13:08:10Z
dc.identifier
https://doi.org/10.1186/s13620-018-0137-x
dc.identifier
0368-0762
dc.identifier
http://hdl.handle.net/10459.1/65584
dc.identifier.uri
http://hdl.handle.net/10459.1/65584
dc.description.abstract
Background: The dimensions of the left atrium in cases with mitral regurgitation are an indirect measurement of its severity. The objective of this study was to evaluate the value of a new radiographic measurement, the radiographic left atrial dimension (RLAD), for detecting left atrial enlargement (LAE) in dogs. Thirty one dogs without LAE and 46 dogs with LAE were recruited in a prospective fashion. Reference left atrium dimension was measured by standard left atrium to aorta ratio (LA/Ao) by 2D echocardiography. LAE was considered if LA/Ao > 1.6. Left atrium dimension was then quantified on lateral radiographs by measuring RLAD. Vertebral heart size (VHS) was measured and RLAD was obtained by drawing a line bisecting the 90 degrees angle defined by the long and short cardiac axes lines of the VHS, up to the dorsal edge of the left atrium and comparing its length to T4's vertebral body length. The correlation of VHS and RLAD methods with LA/Ao was estimated, as well as their sensitivity and specificity for detecting LAE. Receiver Operating Characteristic (ROC) curves were used to estimate the optimal decision criteria for each method. Results: A positive correlation was observed between RLAD and LA/Ao (r = 0.82). RLAD's sensitivity and specificity for detecting LAE when evaluated at the optimal cut-off value, 1.8 vertebrae, were 93.5 and 96.8% respectively. RLAD showed high reproducibility and repeatability. Conclusion: RLAD appears to be a clinically useful radiographic measurement for evaluating left atrial dimensions. RLAD would provide clinicians with a simple and cost-effective tool for evaluating and monitoring LAE.
dc.format
application/pdf
dc.language
eng
dc.publisher
BMC
dc.relation
Reproducció del document publicat a: https://doi.org/10.1186/s13620-018-0137-x
dc.relation
Irish Veterinary Journal, 2018, vol. 71, núm. 25, p. 1-7
dc.rights
cc-by (c) Sánchez et al., 2018
dc.rights
info:eu-repo/semantics/openAccess
dc.rights
http://creativecommons.org/licenses/by/4.0/es
dc.subject
Dog
dc.subject
Left atrial size
dc.subject
Mitral valve disease
dc.subject
Radiographic measurement
dc.title
A radiographic measurement of left atrial size in dogs
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)