4D Flow cardiovascular magnetic resonance consensus statement: 2023 update

dc.contributor
Institut Català de la Salut
dc.contributor
[Bissell MM] Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), LIGHT Laboratories, Clarendon Way, University of Leeds, Leeds LS2 9NL, UK. [Raimondi F] Children’s Hospital Meyer, University of Florence, Florence, Italy. [Ait Ali L] Institute of Clinical Physiology CNR, Massa, Italy. Foundation CNR Tuscany Region G. Monasterio, Massa, Italy. [Allen BD] Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA. [Barker AJ] Department of Radiology, Children’s Hospital Colorado, University of Colorado Anschutz Medical Center, Aurora, USA. [Bolger A] Department of Medicine, University of California, San Francisco, CA, USA. Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden. [Rodriguez-Palomares J] Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Bissell, Malenka Mona
dc.contributor.author
Ait Ali, Lamia
dc.contributor.author
Allen, Bradley D.
dc.contributor.author
Barker, Alex
dc.contributor.author
Bolger, Ann
dc.contributor.author
Rodríguez Palomares, José F
dc.contributor.author
Raimondi, Francesca
dc.date.issued
2023-08-23T07:46:17Z
dc.date.issued
2023-08-23T07:46:17Z
dc.date.issued
2023-07-20
dc.identifier
Bissell MM, Raimondi F, Ait Ali L, Allen BD, Barker AJ, Bolger A, et al. 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update. J Cardiovasc Magn Reson. 2023 Jul 20;25:40.
dc.identifier
1532-429X
dc.identifier
https://hdl.handle.net/11351/10132
dc.identifier
10.1186/s12968-023-00942-z
dc.identifier
37474977
dc.identifier
001030669300002
dc.description.abstract
4D Flow MRI; Hemodynamics; Recommendations
dc.description.abstract
Ressonància magnètica de flux 4D; Hemodinàmica; Recomanacions
dc.description.abstract
Resonancia magnética de flujo 4D; Hemodinámica; Recomendaciones
dc.description.abstract
Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 ‘4D Flow CMR Consensus Statement’. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.
dc.description.abstract
1R01HL149787-01A1 (S. Schnell, M. Markl), 1R21NS122511-01 (S. Schnell), 1R01CA233878-01 (J.Collins) J.Sotelo thanks to ANID–Millennium Science Initiative Program–ICN2021_004 and FONDECYT de iniciación en investigación #11200481. Dr. Oechtering receives funding from the German Research Foundation (OE 746/1-1).
dc.format
application/pdf
dc.language
eng
dc.publisher
BMC
dc.relation
Journal of Cardiovascular Magnetic Resonance;25
dc.relation
https://doi.org/10.1186/s12968-023-00942-z
dc.rights
Attribution 4.0 International
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Scientia
dc.subject
Sistema cardiovascular - Malalties
dc.subject
Imatgeria per ressonància magnètica
dc.subject
Flux sanguini
dc.subject
DISEASES::Cardiovascular Diseases
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Tomography::Magnetic Resonance Imaging
dc.subject
PHENOMENA AND PROCESSES::Circulatory and Respiratory Physiological Phenomena::Cardiovascular Physiological Phenomena::Hemodynamics::Hemorheology::Blood Flow Velocity
dc.subject
ENFERMEDADES::enfermedades cardiovasculares
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::tomografía::imagen por resonancia magnética
dc.subject
FENÓMENOS Y PROCESOS::fenómenos fisiológicos respiratorios y circulatorios::fenómenos fisiológicos cardiovasculares::hemodinámica::hemorreología::velocidad del flujo sanguíneo
dc.title
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)