[Tobías-Castillo PE, Martí-Aguasca G] Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Oristrell G] Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBER CV), Instituto de Salud Carlos III, Madrid, Spain. [Reyes-Juárez JL] Servei de Radiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain

Vall d'Hebron Barcelona Hospital Campus

Publication date

2023-09-19T09:07:01Z

2023-09-19T09:07:01Z

2023-09



Abstract

Pseudoaneurisma aòrtic; Tancament percutani; Síncope


Pseudoaneurisma aórtico; Cierre percutáneo; Síncope


Aortic pseudoaneurysm; Percutaneous closure; Syncope


Background Ascending aortic pseudoaneurysms (AAPs) are an unusual complication of cardiac or aortic surgery and are associated with a high risk of complications and mortality. Guidelines recommend surgical repair. There is few data concerning percutaneous occlusion of AAP. We present a case of syncope due to vascular and heart chamber compression by a large post-surgical AAP that was filled through a focal leak. Ascending aortic pseudoaneurysm was successfully occluded percutaneously. Case summary A 66-year-old man with a mechanical aortic prosthesis and a Dacron tube in the ascending aorta presented with syncope due to compression of the right atrium and superior vena cava by a large peritube collection. A computed tomography angiography (CTA) showed a large AAP that was filled through a small focal dehiscence of the tube proximal suture. Patient was dismissed for surgery due to high surgical risk. Then, AAP was successfully occluded percutaneously via a 6-French radial access and local anaesthesia. Discussion In patients with syncope and previous cardiac surgery, aortic complications should be ruled out. Although transthoracic echocardiography may be useful, CTA is the recommended diagnostic test for ruling out post-surgical AAP and allows the characterization of the number, localization, and size of the leaks. In selected patients with high surgical risk and favourable anatomic characteristics, a percutaneous closure could be indicated.

Document Type

Article


Published version

Language

English

Subjects and keywords

Aneurismes aòrtics - Cirurgia; Cor - Cirurgia - Complicacions; Angiografia; ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Surgical Procedures, Operative::Cardiovascular Surgical Procedures::Cardiac Surgical Procedures; Other subheadings::Other subheadings::Other subheadings::/adverse effects; DISEASES::Cardiovascular Diseases::Vascular Diseases::Aneurysm::Aneurysm, False; Other subheadings::Other subheadings::Other subheadings::/surgery; ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Image Interpretation, Computer-Assisted::Tomography, X-Ray Computed::Computed Tomography Angiography; TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::intervenciones quirúrgicas::procedimientos quirúrgicos cardiovasculares::procedimientos quirúrgicos cardíacos; Otros calificadores::Otros calificadores::Otros calificadores::/efectos adversos; ENFERMEDADES::enfermedades cardiovasculares::enfermedades vasculares::aneurisma::aneurisma falso; Otros calificadores::Otros calificadores::Otros calificadores::/cirugía; TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::interpretación de imágenes asistida por ordenador::tomografía computarizada por rayos X::angiografía por tomografía computarizada

Publisher

Oxford University Press

Related items

European Heart Journal - Case Reports;7(9)

https://doi.org/10.1093/ehjcr/ytad414

Recommended citation

This citation was generated automatically.

Rights

Attribution-NonCommercial 4.0 International

http://creativecommons.org/licenses/by-nc/4.0/

This item appears in the following Collection(s)