Impact of the restrictive technique on outcomes in Baerveldt-350 implant surgery

dc.contributor
Institut Català de la Salut
dc.contributor
[Segura-Duch G] Ophthalmology, Verte-ICO Oftalmología, Barcelona, Spain. Oftalmology, Centro de Oftalmología Barraquer, Barcelona, Spain. [Oliver-Gutierrez D] Ophthalmology, Verte-ICO Oftalmología, Barcelona, Spain. Servei d’Oftalmologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Duch S, Arciniegas-Perasso C] Ophthalmology, Verte-ICO Oftalmología, Barcelona, Spain. [Schilt M] Ophthalmology, Verte-ICO Oftalmología, Barcelona, Spain. Ophtalmology, Hospital Municipal de Badalona, Badalona, Spain
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Segura-Duch, Gloria
dc.contributor.author
Duch, Susana
dc.contributor.author
Schilt-Catafal, Maria del Mar
dc.contributor.author
Arciniegas-Perasso, Carlos
dc.contributor.author
Oliver-Gutierrez, David
dc.date.accessioned
2025-10-24T10:37:54Z
dc.date.available
2025-10-24T10:37:54Z
dc.date.issued
2025-04-11T11:58:26Z
dc.date.issued
2025-04-11T11:58:26Z
dc.date.issued
2025-02-13
dc.identifier
Segura-Duch G, Oliver-Gutierrez D, Duch S, Schilt M, Arciniegas-Perasso C. Impact of the restrictive technique on outcomes in Baerveldt-350 implant surgery. BMJ Open Ophthalmol. 2025 Feb 13;10(1):e001879.
dc.identifier
2397-3269
dc.identifier
http://hdl.handle.net/11351/12943
dc.identifier
10.1136/bmjophth-2024-001879
dc.identifier
39947710
dc.identifier
001421813900001
dc.identifier.uri
https://hdl.handle.net/11351/12943
dc.description.abstract
Glaucoma; Presión intraocular; Tratamiento quirúrgico
dc.description.abstract
Glaucoma; Pressió intraocular; Tractament quirúrgic
dc.description.abstract
Glaucoma; Intraocular pressure; Treatment surgery
dc.description.abstract
Background Different aqueous restrictive manoeuvres in non-valved devices affect intraocular pressure (IOP) levels in the first postoperative month. This study compares tube ligature (TL) alone to TL plus rip cord stent (TLS) on the efficacy of the Baerveldt 350. Methods We conducted a retrospective consecutive case-series observational study to assess efficacy by measuring IOP, success rates and the reduction of antiglaucoma medication usage over 3 years. Results The study included 43 eyes in the TL group and 29 in the TLS group. Initial IOPs were 26.67 mm Hg for TL and 28.21 mm Hg for TLS. After 1 year, IOP decreased to 13.03 mm Hg and 12.11 mm Hg, respectively. Over 3 years, TLS consistently achieved greater reductions in IOP compared with TL, with significant differences of 3.56 mm Hg in the second year (p=0.01) and 3.34 mm Hg in the third year (p=0.01). Mean antiglaucoma medication use decreased from 3.03 (SD 1.29) to 0.72 (SD 0.47) over 3 years, representing a 76.24% reduction, with no differences between the TL and TLS groups. Failure rate at 1 year was significantly lower for TLS under the success criteria of IOP=(6–18) mm Hg (TL: 33.33%, TLS: 7.14%, p=0.02). Rates of transient hypotension and hypertensive phase were higher in the TL group: 93.02% vs 34.48% (p<0.001) and 58.14% vs 32.14% (χ²=4.59, p=0.03), respectively. Conclusion Adding the rip cord stent to the Baerveldt implant significantly enhances long-term IOP control and reduces failure rates compared with TL alone. The lower incidence of hypertensive phases could be due to sequential tube opening. Small sample size, lack of randomisation and follow-up discrepancies may introduce bias and limit statistical power, highlighting the need for further research to confirm these conclusions.
dc.format
application/pdf
dc.language
eng
dc.publisher
BMJ
dc.relation
BMJ Open Ophthalmology;10(1)
dc.relation
https://doi.org/10.1136/bmjophth-2024-001879
dc.rights
Attribution-NonCommercial 4.0 International
dc.rights
http://creativecommons.org/licenses/by-nc/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Scientia
dc.subject
Glaucoma - Cirurgia
dc.subject
Pressió intraocular
dc.subject
Lents intraoculars
dc.subject
Pròtesis de Stent
dc.subject
DISEASES::Eye Diseases::Ocular Hypertension::Glaucoma
dc.subject
Other subheadings::Other subheadings::Other subheadings::/surgery
dc.subject
PHENOMENA AND PROCESSES::Ocular Physiological Phenomena::Intraocular Pressure
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Equipment and Supplies::Prostheses and Implants::Glaucoma Drainage Implants
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Equipment and Supplies::Prostheses and Implants::Stents
dc.subject
ENFERMEDADES::oftalmopatías::hipertensión ocular::glaucoma
dc.subject
Otros calificadores::Otros calificadores::Otros calificadores::/cirugía
dc.subject
FENÓMENOS Y PROCESOS::fenómenos fisiológicos oculares::presión intraocular
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::equipos y suministros::prótesis e implantes::implantes de drenaje del glaucoma
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::equipos y suministros::prótesis e implantes::stents
dc.title
Impact of the restrictive technique on outcomes in Baerveldt-350 implant surgery
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)