Efficacy and Safety of Ab Externo Open Conjunctiva XEN® 63 µm Implantation with a 30G Needle Scleral Tract in Primary Open-Angle Glaucoma

dc.contributor
Institut Català de la Salut
dc.contributor
[Bertolani Y, Rigo-Quera J, Sánchez-Vela L, Pujol-Carreras O, Amilburu M, Dou A, Castany M] Servei d’Oftalmologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain
dc.contributor
Vall d'Hebron Barcelona Hospital Campus
dc.contributor.author
Rigo-Quera, Jaume
dc.contributor.author
Sánchez-Vela, Laura
dc.contributor.author
Pujol, Olívia
dc.contributor.author
Amilburu, Manuel
dc.contributor.author
Dou, Antonio
dc.contributor.author
Bertolani, Yann
dc.contributor.author
Castany, Marta
dc.date.accessioned
2025-10-24T10:42:41Z
dc.date.available
2025-10-24T10:42:41Z
dc.date.issued
2025-06-13T08:21:58Z
dc.date.issued
2025-06-13T08:21:58Z
dc.date.issued
2025-05
dc.identifier
Bertolani Y, Rigo-Quera J, Sánchez-Vela L, Pujol-Carreras O, Amilburu M, Dou A, et al. Efficacy and Safety of Ab Externo Open Conjunctiva XEN® 63 µm Implantation with a 30G Needle Scleral Tract in Primary Open-Angle Glaucoma. J Clin Med. 2025 May;14(9):3195.
dc.identifier
2077-0383
dc.identifier
http://hdl.handle.net/11351/13270
dc.identifier
10.3390/jcm14093195
dc.identifier
40364226
dc.identifier
001486509400001
dc.identifier.uri
https://hdl.handle.net/11351/13270
dc.description.abstract
Intraocular surgery; Minimally invasive glaucoma surgery; Primary open-angle glaucoma
dc.description.abstract
Cirurgia intraocular; Abordatge conjuntival obert; Glaucoma primari d'angle obert
dc.description.abstract
Cirugía intraocular; Abordaje conjuntival abierto; Glaucoma primario de ángulo abierto
dc.description.abstract
Background: This study aimed to assess the efficacy and safety of the 30G needle mediated ab externo open conjunctiva approach for the XEN 63 µm implant in primary open-angle glaucoma. Methods: A retrospective and non-randomized study was conducted on consecutive cases of medically refractory primary open-angle glaucoma treated with standalone ab externo open conjunctiva XEN® 63 µm (North Chicago, Illinois) with one-year follow-up. Results: Twenty-two eyes were included. The mean preoperative intraocular pressure was 21.9 ± 7.2 mmHg, and the mean number of glaucoma medications was 2.4 ± 0.9. All patients underwent mitomycin 0.02% application for 2 min, and Healaflow® (MedicalMix, Spain), was implanted in 11 cases (50%). Complete surgical success was achieved in 14 cases (63.6%). No statistical differences in complete surgical success were noted based on the use of Healaflow®. A significant reduction in intraocular pressure (11.8 ± 3.4 mmHg) and in the number of hypotensive medications (0.2 ± 0.5 mmHg) was observed 1 year after the procedure. Transient hypotony was detected in 31.8% of cases. Complications secondary to hypotony included four cases of serous choroidal detachment and one case of localized hemorrhagic choroidal detachment, the latter associated with hypotonic keratopathy and hypotonic maculopathy. All these complications evolved favorably with conservative management and adjusted topical treatment. Conclusions: This study highlights the efficacy and safety of this approach for the XEN 63 µm implant in medically refractory primary open-angle glaucoma.
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI
dc.relation
Journal of Clinical Medicine;14(9)
dc.relation
https://doi.org/10.3390/jcm14093195
dc.rights
Attribution 4.0 International
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Scientia
dc.subject
Avaluació de resultats (Assistència sanitària)
dc.subject
Glaucoma d'angle obert - Cirurgia
dc.subject
Pròtesis de Stent
dc.subject
Pressió intraocular
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Diagnosis::Prognosis::Treatment Outcome
dc.subject
DISEASES::Eye Diseases::Ocular Hypertension::Glaucoma::Glaucoma, Open-Angle
dc.subject
Other subheadings::Other subheadings::Other subheadings::/surgery
dc.subject
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT::Equipment and Supplies::Prostheses and Implants::Glaucoma Drainage Implants
dc.subject
Intraocular Pressure
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::diagnóstico::pronóstico::resultado del tratamiento
dc.subject
ENFERMEDADES::oftalmopatías::hipertensión ocular::glaucoma::glaucoma de ángulo abierto
dc.subject
Otros calificadores::Otros calificadores::Otros calificadores::/cirugía
dc.subject
TÉCNICAS Y EQUIPOS ANALÍTICOS, DIAGNÓSTICOS Y TERAPÉUTICOS::equipos y suministros::prótesis e implantes::implantes de drenaje del glaucoma
dc.subject
FENÓMENOS Y PROCESOS::fenómenos fisiológicos oculares::presión intraocular
dc.title
Efficacy and Safety of Ab Externo Open Conjunctiva XEN® 63 µm Implantation with a 30G Needle Scleral Tract in Primary Open-Angle Glaucoma
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)