Diagnostic accuracy and detection rate of glaucoma screening with optic disk photos, optical coherence tomography images, and telemedicine
Anton, Alfonso; Nolivos, Karen; Pazos, Marta; Fatti, Gianluca; Ayala, Miriam Eleonora; Martínez-Prats, Elena; Peral, Oscar; Poposki, Vladimir; Tsiroukis, Evangelos; Morilla-Grasa, Antonio; Comas, Merce; Castells, Xavier
Purpose: The aim of this study was to evaluate the diagnostic accuracy of optical coherence tomography (OCT) and retinography in the detection of glaucoma through a telemedicine program. Methods: A population-based sample of 4113 persons was randomly selected. The screening examination included a fundus photograph and OCT images. Images were evaluated on a deferred basis. All participants were then invited to a complete glaucoma examination, including gonioscopy, visual field, and dilated fundus examination. The detection rate, sensitivity, specificity, and positive and negative predictive values were calculated. Results: We screened 1006 persons. Of these, 201 (19.9%) were classified as glaucoma suspects; 20.4% were identified only by retinographs, 11.9% only by OCT images, and 46.3% by both. On ophthalmic examination at the hospital (n = 481), confirmed glaucoma was found in 58 (12.1%), probable glaucoma in 76 (15.8%), and ocular hypertension in 10 (2.1%), and no evidence of glaucoma was found in 337 (70.0%). The detection rate for confirmed or probable glaucoma was 9.2%. Sensitivity ranged from 69.4% to 86.2% and specificity from 82.1% to 97.4%, depending on the definition applied. Conclusions: The combination of OCT images and fundus photographs yielded a detection rate of 9.2% in a population-based screening program with moderate sensitivity, high specificity, and predictive values of 84–96%.
-Glaucoma
-Tomografia de coherència òptica
-Retinografia
-Telemedicina
-Projecció
-Glaucoma
-Tomografía de coherencia óptica
-Retinografía
-Telemedicina
-Proyección
-Glaucoma
-Optical coherence tomography
-Retinography
-Telemedicine
-Screening
-61
-617
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
https://creativecommons.org/licenses/by/4.0/
Article
Article - Versió publicada
MDPI
         

Mostra el registre complet del document

Documents relacionats

Altres documents del mateix autor/a

Antón López, Alfonso; Nolivos, Karen; Pazos, Marta; Fatti, Gianluca; Herranz, Alejandra; Ayala-Fuentes, Miriam Eleonora; Martínez-Prats, Elena; Peral, Oscar; Vega-Lopez, Zaida; Monleon-Getino, Antoni; Morilla Grasa, Antonio; Comas, Merce; Castells, Xavier
Antón López, Alfonso; Fallon, Monica; Cots Reguant, Francesc; Sebastian, María A.; Morilla-Grasa, Antonio; Mojal, Sergi; Castells, Xavier
Dyrda, Agnieszka; Antón López, Alfonso; Figueroa-Vercellino, Juan Pablo; Pazos, Marta
Dyrda, Agnieszka; Martínez-Palmer, A.R.; Martı́n-Moral, Daniel; Rey, Amanda; Morilla-Grasa, Antonio; Castilla-Martí, Miguel; Aronés-Santivañez, Janny
Gómez-Valverde, Juan J.; Antón López, Alfonso; Fatti, Gianluca; Liefers, Bart; Herranz, Alejandra; Santos, Andrés; Sánchez, Clara I.; Ledesma-Carbayo, María J.