Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial; Institut de Robòtica i Informàtica Industrial; Universitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control; Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control |
Abstract:
|
This paper presents an optimal sensor placement strategy based on pressure sensitivity matrix analysis
and a semi-exhaustive search strategy that maximizes some diagnosis specifications for water distribution networks.
A mean average worst leak expansion distance has been proposed as a new leak location performance measure.
The approach is combined with a clustering technique in order to reduce the size and the complexity of the sensor
placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a
district metered area (DMA) in the Barcelona water distribution network (WDN). |
Abstract:
|
Peer Reviewed |
Materia(s):
|
-Àrees temàtiques de la UPC::Informàtica::Automàtica i control -Water-supply -Uncertainty -Mathematical models -Detectors -Pressure -matrix algebra -monitoring -pattern clustering -pressure sensors -query formulation -water supply -leak monitoring -drinking water networks -clustering techniques -optimal sensor placement -pressure sensitivity matrix analysis -semi-exhaustive search strategy -pressure sensors -district metered area -DMA -Barcelona water distribution network -WDN -Aigua--Abastament -Incertesa -Models matemàtics -Detectors -Pressió |