Testing the performance of sensors for ozone pollution monitoring in a citizen science approach
Ripoll Ruiz, Aleix; Viana, Mar; Padrosa, Marc; Querol Carceller, Xavier; Minutolo, Andrea; Hou, Kun Mean; Barceló Ordinas, José María; García Vidal, Jorge
Universitat Politècnica de Catalunya. Departament d'Arquitectura de Computadors; Universitat Politècnica de Catalunya. CNDS - Xarxes de Computadors i Sistemes Distribuïts
Tropospheric ozone (O3) is an environmental pollutant of growing concern, especially in suburban and rural areas where the density of air quality monitoring stations is not high. In this type of areas citizen science strategies can be useful tools for awareness raising, but sensor technologies must be validated before sensor data are communicated to the public. In this work, the performance under field conditions of two custom-made types of ozone sensing devices, based on metal-oxide and electrochemical sensors, was tested. A large array of 132 metal-oxide (Sensortech MICS 2614) and 11 electrochemical (Alphasense) ozone sensors, built into 44 sensing devices, was co-located at reference stations in Italy (4 stations) and Spain (5). Mean R2 between sensor and reference data was 0.88 (0.78–0.96) and 0.89 (0.73–0.96) for Captor (metal-oxide) and Raptor (electrochemical) nodes. The metal-oxide sensors showed an upper limit (approximately 170 µg/m3) implying that these sensors may be useful to communicate mean ozone concentrations but not peak episodes. The uncertainty of the nodes was 10% between 100 and 150 µg/m3 and 20% between 150 and 200 µg/m3, for Captors, and 10% for >100 µg/m3 for Raptors. Operating both types of nodes up to 5 months did not evidence any clear influence of drifts. The use of these sensors in citizen science can be a useful tool for awareness raising. However, significant data processing efforts are required to ensure high data quality, and thus machine learning strategies are advisable. Relative uncertainties should always be reported when communicating ozone concentration data from sensing nodes.
Peer Reviewed
-Àrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura::Sensors i actuadors
-Pollution control equipment
-Air -- Pollution
-Electrochemical sensors
-Uncertainty
-Low-cost sensors
-Validation
-Performance
-Awareness
-Platform
-Node
-Contaminació -- Control -- Aparells i accessoris
-Aire -- Contaminació
-Sensors electroquímics
Attribution-NonCommercial-NoDerivs 3.0 Spain
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
Article - Published version
Article
Elsevier
         

Show full item record

Related documents

Other documents of the same author

Barceló Ordinas, José María; Ferrer Cid, Pau; García Vidal, Jorge; Ripoll, Anna; Viana, Mar
Ferrer Cid, Pau; Barceló Ordinas, José María; García Vidal, Jorge; Ripoll, Anna; Viana, Mar
Barceló Ordinas, José María; García Vidal, Jorge; Doudou, Messaoud; Rodrigo Muñoz, Santiago; Cerezo Llavero, Albert
Incebacak, Davut; Zilan, Ruken; Tavli, Bulent; Barceló Ordinas, José María; García Vidal, Jorge
Barceló Ordinas, José María; Doudou, Messaoud; García Vidal, Jorge; Badache, Nadjib
 

Coordination

 

Supporters