Development and Validation of a New High-Performance Liquid Chromatography Method for the Simultaneous Quantification of Coenzyme Q10, Phosphatidylserine, and Vitamin C from a Cutting-Edge Liposomal Vehiculization

dc.contributor.author
Ruiz García, Marta
dc.contributor.author
Pérez Lozano, Pilar
dc.contributor.author
Mercadé Frutós, Débora
dc.contributor.author
Nardi Ricart, Anna
dc.contributor.author
Suñé Pou, Marc
dc.contributor.author
Cano-Sarabia, Mary
dc.contributor.author
García Jimeno, Sonia
dc.contributor.author
Suñé-Negre, Josep Maria
dc.contributor.author
Maspoch Comamala, Daniel
dc.contributor.author
García Montoya, Encarna
dc.date.issued
2019
dc.identifier
https://ddd.uab.cat/record/222259
dc.identifier
urn:10.1021/acsomega.9b02456
dc.identifier
urn:oai:ddd.uab.cat:222259
dc.identifier
urn:pmid:31788602
dc.identifier
urn:scopus_id:85074983335
dc.identifier
urn:articleid:24701343v4n22p19710
dc.identifier
urn:wos_id:000499133200022
dc.identifier
urn:pmc-uid:6881841
dc.identifier
urn:pmcid:PMC6881841
dc.identifier
urn:oai:pubmedcentral.nih.gov:6881841
dc.identifier
urn:icn2uab:5990188
dc.identifier
urn:oai:egreta.uab.cat:publications/4073c0fb-bdaf-49b6-b6fc-4fb0de282cde
dc.description.abstract
This is an open access article published under an ACS AuthorChoice License. See Standard ACS AuthorChoice/Editors' Choice Usage Agreement - https://pubs.acs.org/page/policy/authorchoice_termsofuse.html
dc.description.abstract
A high-performance liquid chromatography (HPLC) method was developed to simultaneously quantify three widely used active substances such as coenzyme Q10, phosphatidylserine, and vitamin C. This new method optimizes current timing and costs in the analyses of these three active substances. Additionally, since the analyzed compounds were encapsulated on a cutting-edge liposomal formulation, further processing was necessary to be developed prior to HPLC analyses. The technique was studied and adequately validated in accordance with the guidelines of the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) regarding selectivity, linearity, accuracy, precision, and robustness. After data treatment of results, linear regressions for all active substances showed an optimal linearity with a correlation coefficient of >0.999 in the concentration range between 70 to 130% of the liposomal formulation and less than a 3% relative standard deviation (RSD) in accuracy and precision.
dc.format
application/pdf
dc.language
eng
dc.publisher
dc.relation
Ministerio de Economía y Competitividad SEV-2017-0706
dc.relation
ACS omega ; Vol. 4, Issue 22 (November 2019), p. 19710-19715
dc.rights
open access
dc.rights
Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original.
dc.rights
https://creativecommons.org/licenses/by-nc/4.0/
dc.subject
Nutrition
dc.subject
High-performance liquid chromatography
dc.subject
Solvents
dc.subject
Organic compounds
dc.title
Development and Validation of a New High-Performance Liquid Chromatography Method for the Simultaneous Quantification of Coenzyme Q10, Phosphatidylserine, and Vitamin C from a Cutting-Edge Liposomal Vehiculization
dc.type
Article


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.