dc.contributor.author
Campos, Bieito
dc.contributor.author
Alonso-Martin, Concepción
dc.contributor.author
Guerra Ramos, José María
dc.contributor.author
Moreno Weidmann, Zoraida
dc.contributor.author
Méndez-Zurita, Francisco
dc.contributor.author
Montiel-Quintero, Rodolfo
dc.contributor.author
Betancur-Gutiérrez, Andrés
dc.contributor.author
Viñolas, Xavier
dc.contributor.author
Rodríguez-Font, Enrique
dc.contributor.author
Universitat Autònoma de Barcelona
dc.identifier
https://ddd.uab.cat/record/282358
dc.identifier
urn:10.3389/fcvm.2023.1162197
dc.identifier
urn:oai:ddd.uab.cat:282358
dc.identifier
urn:pmcid:PMC10280734
dc.identifier
urn:pmc-uid:10280734
dc.identifier
urn:pmid:37346283
dc.identifier
urn:oai:pubmedcentral.nih.gov:10280734
dc.identifier
urn:oai:egreta.uab.cat:publications/55e988b0-4dae-4f35-be0e-93c7b18becf7
dc.description.abstract
Circumferential ablation around the ipsilateral pulmonary veins (PVs) is the standard strategy for atrial fibrillation ablation. The present study seeks to assess which regions of the standard ablation circumference are the main contributors to the venoatrial electrical connection. A total of 41 patients were included under a specific atrial fibrillation ablation protocol in which the anterior and posterior segments of the standard circumference, between the equatorial line of the superior and the inferior ipsilateral PVs, were ablated first. If PV isolation was not achieved, ablation was extended superiorly or inferiorly, on the basis of the earliest atrial activation recorded during pacing from inside the PV. Complete PV isolation and the length of the areas not requiring ablation (ANRA) at the time of electrical isolation were evaluated. Ablation of the anterior and posterior segments of the standard circumference led to the isolation of 77% left-PV pairs and 51% right-PV pairs (p = 0,015). A superior extension was required in 23% left-PV pairs and in 46% right-PV pairs, while an inferior extension was required only in 10% left-PV pairs and in 11% right-PV pairs. PV isolation was achieved before completing the standard ablation circumference in 97% left-PV pairs and in 94% right-PV pairs, with a median ANRA of 36.9 (IQR: 30.9-42.1) mm in the left PVs [16.0 (IQR: 12.0-19.0) mm superior and 18.8 (IQR: 16.1-24.9) mm inferior, p < 0.01] and 36.9 (IQR: 30.2-41.0) mm in the right PVs [15.1 (IQR: 10.7-19.1) mm superior and 20.6 (IQR: 16.9-23.3) mm inferior, p < 0.01]. The myocardial fibers along the anterior and posterior regions of the standard ablation circumference are the main contributors to the electrical connection between the pulmonary veins and the left atrium. Ablation of these regions results in PV isolation in the majority of patients.
dc.format
application/pdf
dc.relation
Frontiers in Cardiovascular Medicine ; Vol. 10 (june 2023)
dc.rights
Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original.
dc.rights
https://creativecommons.org/licenses/by/4.0/
dc.subject
Atrial fibrillation
dc.subject
Electrical connection
dc.subject
Myocardial fiber
dc.subject
Pulmonary vein
dc.title
Reassessment of the electrical connection between the pulmonary veins and the left atrium : A study to determine the different contributions of myocardial fibers along the standard ablation circumference