Effect of lung volume preservation during spontaneous breathing trial on successful extubation in patients receiving mechanical ventilation : protocol for a multicenter clinical trial

dc.contributor.author
Subirà, Carles
dc.contributor.author
Rognoni, Gina
dc.contributor.author
Baquerizo, Herbert
dc.contributor.author
García, Carolina
dc.contributor.author
Cabañes, Sara
dc.contributor.author
de la Torre, Maria
dc.contributor.author
Quevedo, Beatriz
dc.contributor.author
Pedrós, Cristina
dc.contributor.author
Tizón, Ana I.
dc.contributor.author
Murillo, Natalia
dc.contributor.author
Parro, Laura
dc.contributor.author
Eiras, Fernando
dc.contributor.author
Rialp, Gemma
dc.contributor.author
Altaba, Susana
dc.contributor.author
González-Castro, Alejandro
dc.contributor.author
Pacheco, Andrés
dc.contributor.author
Bayoumi, Pablo
dc.contributor.author
Gómez-Medrano, Norma
dc.contributor.author
Vallverdú, Imma
dc.contributor.author
Higón, Áurea
dc.contributor.author
Navarro, María D.
dc.contributor.author
Falcón, Alirio
dc.contributor.author
Keough, Elena
dc.contributor.author
Arizo, David
dc.contributor.author
Martínez, Juan F.
dc.contributor.author
Durán, Núria
dc.contributor.author
Rodríguez, Raquel
dc.contributor.author
Popoviciu-Koborzan, Melinda R.
dc.contributor.author
Guerrero, Isabel
dc.contributor.author
Concha, Pablo
dc.contributor.author
Barral, Patricia
dc.contributor.author
Batlle, Montserrat
dc.contributor.author
Cano, Sílvia
dc.contributor.author
Garcia-Castrillon, Silvia
dc.contributor.author
Andorrà, Xavier
dc.contributor.author
Tua, Yenifher
dc.contributor.author
Arnau, Anna
dc.contributor.author
Fernández, Rafael
dc.contributor.author
Universitat Autònoma de Barcelona
dc.date.issued
2024
dc.identifier
https://ddd.uab.cat/record/308061
dc.identifier
urn:10.1186/s13063-024-08297-1
dc.identifier
urn:oai:ddd.uab.cat:308061
dc.identifier
urn:scopus_id:85198722029
dc.identifier
urn:articleid:17456215v25n1p481
dc.identifier
urn:pmid:39014430
dc.identifier
urn:pmc-uid:11251308
dc.identifier
urn:pmcid:PMC11251308
dc.identifier
urn:oai:pubmedcentral.nih.gov:11251308
dc.description.abstract
Background: In standard weaning from mechanical ventilation, a successful spontaneous breathing test (SBT) consisting of 30 min 8 cmHO pressure-support ventilation (PSV8) without positive end-expiratory pressure (PEEP) is followed by extubation with continuous suctioning; however, these practices might promote derecruitment. Evidence supports the feasibility and safety of extubation without suctioning. Ultrasound can assess lung aeration and respiratory muscles. We hypothesize that weaning aiming to preserve lung volume can yield higher rates of successful extubation. Methods: This multicenter superiority trial will randomly assign eligible patients to receive either standard weaning [SBT: 30-min PSV8 without PEEP followed by extubation with continuous suctioning] or lung-volume-preservation weaning [SBT: 30-min PSV8 + 5 cmHO PEEP followed by extubation with positive pressure without suctioning]. We will compare the rates of successful extubation and reintubation, ICU and hospital stays, and ultrasound measurements of the volume of aerated lung (modified lung ultrasound score), diaphragm and intercostal muscle thickness, and thickening fraction before and after successful or failed SBT. Patients will be followed for 90 days after randomization. Discussion: We aim to recruit a large sample of representative patients (N = 1600). Our study cannot elucidate the specific effects of PEEP during SBT and of positive pressure during extubation; the results will show the joint effects derived from the synergy of these two factors. Although universal ultrasound monitoring of lungs, diaphragm, and intercostal muscles throughout weaning is unfeasible, if derecruitment is a major cause of weaning failure, ultrasound may help clinicians decide about extubation in high-risk and borderline patients. Trial registration: The Research Ethics Committee (CEIm) of the Fundació Unió Catalana d'Hospitals approved the study (CEI 22/67 and 23/26). Registered at ClinicalTrials.gov in August 2023. Identifier: NCT05526053.
dc.format
application/pdf
dc.language
eng
dc.publisher
dc.relation
Trials ; Vol. 25 Núm. 1 (december 2024), p. 481
dc.rights
open access
dc.rights
Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original.
dc.rights
https://creativecommons.org/licenses/by/4.0/
dc.subject
Extubation
dc.subject
Lung ultrasound
dc.subject
Mechanical ventilation
dc.subject
Spontaneous breathing trial
dc.subject
Weaning
dc.title
Effect of lung volume preservation during spontaneous breathing trial on successful extubation in patients receiving mechanical ventilation : protocol for a multicenter clinical trial
dc.type
Article