Sistemes lidar (radar laser) d'ona contínua i baixa potència per a la detecció i mesura de concentració de gasos amb resolució espacial

dc.contributor
Agència de Gestió d'Ajuts Universitaris i de Recerca
dc.contributor
Comerón Tejero, Adolfo
dc.contributor
Universitat Politècnica de Catalunya. Departament de Teoria del Senyal i Comunicacions
dc.contributor.author
Batet Torrell, Oscar
dc.date.accessioned
2010-11-30T08:31:33Z
dc.date.available
2010-11-30T08:31:33Z
dc.date.created
2010-07-20
dc.date.issued
2010-11-30T08:31:33Z
dc.identifier.uri
https://hdl.handle.net/2072/97196
dc.description.abstract
The present project has performed the study and development of a new technique for the detection of gases with range resolution. This technique called FMCW-lidar is a technique that evolves from the FMCW-radar technique to be applied to lidar systems. Moreover, it takes advantage of the appearance of spectral absorption lines because of the interaction between light and gases to tune the light wavelength of a laser emitter with one of this spectral lines and then detects the backscattered light and analyzes it in order to obtain gas concentration measurements. The first part of the project consisted in the analysis of the WMS technique which is a technique for the in-situ measurement of gases. A complete theoretical analysis has been performed and some experiments have been carried out in order to test the technique and to validate its application to an FMCW-modulated system for the detection of gases. The second part of the project consisted in the analysis of the lidar FMCW technique for solid target detection and its extension to continuous media. The classical form of this technique has been analyzed for a distributed medium and a filtering effect has been found which prevents the accurate acquisition of the medium response. A modification of the technique has been proposed and a validation via simulations and some experiments has been carried on. After performing these tests, a novel system is proposed to be developed and tested in order to perform the indicated gas detection with range resolution.
cat
dc.format.extent
47 p.
ca
dc.format.extent
634763 bytes
dc.format.mimetype
application/pdf
dc.language.iso
eng
ca
dc.relation.ispartofseries
Els ajuts de l'AGAUR;2009FIC00138
dc.rights
Aquest document està subjecte a una llicència d'ús de Creative Commons, amb la qual es permet copiar, distribuir i comunicar públicament l'obra sempre que se'n citin l'autor original i l’Agència i no se'n faci cap ús comercial ni obra derivada, tal com queda estipulat en la llicència d'ús (http://creativecommons.org/licenses/by-nc-nd/2.5/es/)
cat
dc.source
RECERCAT (Dipòsit de la Recerca de Catalunya)
dc.subject.other
Teledetecció -- Aparells i instruments
ca
dc.subject.other
Radar òptic
ca
dc.subject.other
Detectors de gasos
ca
dc.title
Sistemes lidar (radar laser) d'ona contínua i baixa potència per a la detecció i mesura de concentració de gasos amb resolució espacial
ca
dc.title.alternative
Continous-wave low-power lidar (radar laser) systems for the detection and mesurement of the gas concentration with range resolution
ca
dc.type
info:eu-repo/semantics/report
ca
dc.subject.udc
621.3
ca


Documents

2009FIC00138_També 2006FI00463.pdf

619.8Kb PDF

Aquest element apareix en la col·lecció o col·leccions següent(s)