Impact of the mechanical interface on BCG signals obtained from electronic weighing scales

dc.contributor
Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.contributor
Universitat Politècnica de Catalunya. GRUP ISI - Grup d'Instrumentació, Sensors i Interfícies
dc.contributor.author
Casanella Alonso, Ramón
dc.contributor.author
Gómez Clapers, Joan
dc.contributor.author
Hernández Urrea, Marc
dc.contributor.author
Pallàs-Areny, Ramon
dc.date.issued
2016
dc.identifier
Casanella, R., Gomez-Clapers, J., Hernandez-Urrea, M., Pallàs-Areny, R. Impact of the mechanical interface on BCG signals obtained from electronic weighing scales. A: Computing in Cardiology Annual Conference. "Computing in Cardiology 2016, Vol. 43". Vancouver: 2016, p. 285-288.
dc.identifier
2325-887X
dc.identifier
https://hdl.handle.net/2117/102902
dc.description.abstract
This work analyzes the reproducibility of the BCG obtained from different weighing scales. First, the natural frequency of three commercial bathroom scales has been characterized by an impulse excitation test. Second, the BCG and the ECG from 5 healthy subjects (27 ± 4 years) have been recorded for 60 s by sequentially standing on these weighing scales connected to the same analog front-end and signal acquisition system. An ensemble average representative of each subject and weighing scale has been obtained by applying Woody’s method with the ECG as a timing reference. Consecutive BCG signals obtained from the three scales show consistent systematic intra-subject differences in the timing of the J peak that can reach up to 30 ms. This timing error is relevant because it is about 50 % of the changes induced by typical respiratory maneuvers, such as Valsalva’s, used to modulate hemodynamic parameters in correlation studies between changes in J timing with respect to different cardiac fiducial points. Due to its ubiquity, weighing scales are promising devices for monitoring cardiovascular function at home but their frequency response must be accounted for and minimal performance standards should be defined for them.
dc.description.abstract
Peer Reviewed
dc.description.abstract
Postprint (published version)
dc.format
4 p.
dc.format
application/pdf
dc.language
eng
dc.relation
http://ieeexplore.ieee.org/document/7868735/
dc.rights
Restricted access - publisher's policy
dc.subject
Àrees temàtiques de la UPC::Enginyeria de la telecomunicació
dc.subject
Electrocardiography
dc.subject
Biomedical engineering
dc.subject
Timing
dc.subject
Electrocardiography
dc.subject
Monitoring
dc.subject
Mechanical factors
dc.subject
Solids
dc.subject
Bandwidth
dc.subject
Hemodynamics
dc.subject
Electrocardiografia
dc.subject
Enginyeria biomèdica
dc.title
Impact of the mechanical interface on BCG signals obtained from electronic weighing scales
dc.type
Conference report


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

E-prints [73034]