Very Low-Noise Differential Radiometer at 30 GHz for the PLANCK LFI

Other authors

Universitat Politècnica de Catalunya. Departament de Teoria del Senyal i Comunicacions

Universitat Politècnica de Catalunya. RF&MW - Grup de Recerca de sistemes, dispositius i materials de RF i microones

Publication date

2005-06-30

Abstract

The PLANCK mission of the European Space Agency is devoted to produce sky maps of the cosmic microwave background radiation. The low-frequency instrument is a wide-band cryogenic microwave radiometer array operating at 30, 44, and 70 GHz. The design, test techniques, and performance of the complete differential radiometer at 30 GHz are presented. This elegant breadboard 30-GHz radiometer is composed of a front-end module (FEM) assembled at the Jodrell Bank Observatory, Cheshire, U.K., and a back-end module assembled at the Universidad de Cantabria, Cantabria, Spain, and Telecomunicacio/spl acute/, Universitat Polite/spl acute/cnica de Catalunya, Barcelona, Spain. The system noise temperature was excellent, mainly due to the very low noise performance of the FEM amplifiers, which achieved an average noise temperature of 9.4 K.


Peer Reviewed

Document Type

Article

Language

English

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC

Recommended citation

This citation was generated automatically.

Rights

Open Access

This item appears in the following Collection(s)

E-prints [72986]