The 234U neutron capture cross section measurement at the n TOF facility

Other authors

Universitat Politècnica de Catalunya. Departament de Física i Enginyeria Nuclear

Universitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions

Publication date

2007

Abstract

The neutron capture cross-section of 234U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n TOF, based on a spallation source located at CERN. A 4π BaF2 array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt γ-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of ENDF in the relevant energy region, indicating the good performance of the n TOF facility and the TAC.


Postprint (published version)

Document Type

Conference report

Language

English

Publisher

EDP Sciences

Related items

http://nd2007.edpsciences.org/articles/ndata/pdf/2007/01/ndata07510.pdf

Recommended citation

This citation was generated automatically.

Rights

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

Open Access

Attribution-NonCommercial-NoDerivs 3.0 Spain

This item appears in the following Collection(s)

E-prints [72987]