Influence mechanism of Steel-concrete interlayer partial shear connections on mechanical properties of composite girders

dc.contributor
Universitat Politècnica de Catalunya. Doctorat en Enginyeria de la Construcció
dc.contributor
Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental
dc.contributor
Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció
dc.contributor.author
Su, Hang
dc.contributor.author
Su, Qingtian
dc.contributor.author
Casas Rius, Joan Ramon
dc.contributor.author
Xu, Chen
dc.contributor.author
Tang, Jian
dc.contributor.author
Jiang, Chao
dc.date.issued
2022-12
dc.identifier
Su, H. [et al.]. Influence mechanism of Steel-concrete interlayer partial shear connections on mechanical properties of composite girders. "Structures", Desembre 2022, vol. 46, p. 503-520.
dc.identifier
2352-0124
dc.identifier
https://hdl.handle.net/2117/376920
dc.identifier
10.1016/j.istruc.2022.10.082
dc.description.abstract
A reduction in composite action using a partial shear connection (PSC) in the hogging moment region of a steel–concrete bridge can mitigate the concrete tensile cracking risk while maintaining the structural ultimate bearing capacity. To date, specific mechanical effects, important for the establishment of evaluation theory, have not been studied. To this end, four girders and six push-out specimens were tested for the effect investigation. Numerical analysis with material damage plasticity models and an analytical study were conducted for parametric and mechanistic investigations. The push-out test results showed that a wrapping rubber sleeve reduced the shear stiffness of the stud by 91.9%, whereas its strength varied slightly. The girder test results showed that arranging rubber sleeved stud (RSS) connectors in the composite girders reduced the girder load-carrying capacity and bending stiffness by 17% and 12%, respectively. Moreover, the concrete tensile cracking performance was improved. The analysis results showed that, for reducing the concrete tensile stress, the RSS connector in the girder had a more favourable effect on prestress distribution than increasing the ordinary stud spacing. In addition, an evident stress concentration appeared when the stud distance was increased. According to the analytical analysis of the girder under negative bending, the concrete tensile stress is exponentially related to the interlayer stud stiffness, and the exponential is expected to be 5/3. The research revealed the detailed mechanical behaviour of the girder with a PSC and simultaneously compared the effects of the two PSC methods. This research will help establish design and evaluation methods for PSC action.
dc.description.abstract
This research was sponsored by the National Natural Science Foundation of China (No. 51978501), Fundamental Research Funds for the Central Universities (No. 22120210437), and China Scholarship Council (No. 202106260050). This support is greatly appreciated.
dc.description.abstract
Peer Reviewed
dc.description.abstract
Postprint (author's final draft)
dc.format
18 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Elsevier
dc.relation
https://www.sciencedirect.com/science/article/abs/pii/S2352012422009791
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
Open Access
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.subject
Àrees temàtiques de la UPC::Enginyeria civil::Materials i estructures
dc.subject
Composite-reinforced concrete
dc.subject
Steel–concrete composite structure
dc.subject
Partial shear connection
dc.subject
Rubber-sleeved stud connector
dc.subject
Numerical study
dc.subject
Experimental study
dc.subject
Hogging moment regions
dc.subject
Materials compostos
dc.title
Influence mechanism of Steel-concrete interlayer partial shear connections on mechanical properties of composite girders
dc.type
Article


Files in this item