Diagonal tension performance of concrete panels reinforced with hooked end steel fibers

dc.contributor
Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental
dc.contributor
Universitat Politècnica de Catalunya. ATEM - Anàlisi i Tecnologia d'Estructures i Materials
dc.contributor.author
Carrillo León, Julián
dc.contributor.author
Murcia Delso, Juan
dc.contributor.author
Massone, Leonardo M.
dc.date.issued
2022-12
dc.identifier
Carrillo, J.; Murcia-Delso, J.; Massone, L. Diagonal tension performance of concrete panels reinforced with hooked end steel fibers. "Engineering structures", Desembre 2022, vol. 272, núm. 114981, p. 1-13.
dc.identifier
0141-0296
dc.identifier
https://www.researchgate.net/publication/363800932_Diagonal_tension_performance_of_concrete_panels_reinforced_with_hooked_end_steel_fibers
dc.identifier
https://hdl.handle.net/2117/377666
dc.identifier
10.1016/j.engstruct.2022.114981
dc.description.abstract
The increase in strength of Steel Fiber Reinforced Concrete (SFRC) depends mainly on factors such as the dosage, aspect ratio and number of hooked ends of the fibers. Previous studies proposed models to estimate the flexural and shear strength of SFRC beams, but the shear behavior of SFRC panels has not been extensively studied. The study includes diagonal tension tests on concrete panels to assess the shear performance of SFRC. The experimental program comprises 19 square concrete panels having 600 mm side and 75 mm thickness, including three nominal dosages of steel fibers (20, 40 and 60 kg/m3) and three different number of hooked ends (1, 1.5 and 2). The study proposes models to predict the shear strength and deformation capacity, stiffness degradation and toughness of SFRC panels with different number of hooked ends when subjected to diagonal tension. The models include four characteristic limit states of diagonal cracking, maximum residual strength, code-based acceptable degradation, and maximum deformation.
dc.description.abstract
The authors thank to Vicerrectoría de Investigaciones of UMNG for the financial support of the EXT-INV-3575 project. The authors also would like to thank Research Assistants Juan D. Vargas and Diego Silva at Universidad Militar Nueva Granada (UMNG) for data and figure processing. The authors also thank the companies Cemex-Colombia and Proalco-Bekaert-Colombia for supplying the concrete and steel fibers, respectively. All data that support the findings of this study are available from the corresponding author upon reasonable request. The views expressed in this paper are solely those of the authors and do not necessarily reflects the views of the sponsors.
dc.description.abstract
Peer Reviewed
dc.description.abstract
Postprint (author's final draft)
dc.format
13 p.
dc.format
application/pdf
dc.language
eng
dc.relation
https://www.sciencedirect.com/science/article/abs/pii/S0141029622010574
dc.rights
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights
Open Access
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.subject
Àrees temàtiques de la UPC::Edificació::Materials de construcció::Formigó
dc.subject
Reinforced concrete construction
dc.subject
Shear strength
dc.subject
Concrete panels
dc.subject
Steel fibers
dc.subject
Failure modes
dc.subject
Stiffness degradation
dc.subject
Energy dissipation
dc.subject
Diagonal tension
dc.subject
Construcció en formigó armat amb fibres
dc.title
Diagonal tension performance of concrete panels reinforced with hooked end steel fibers
dc.type
Article


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

E-prints [72950]