Educational buildings often face significant challenges with indoor air quality and thermal comfort, mainly due to a lack of mechanical ventilation and air conditioning systems. Research has demonstrated that these issues negatively affect students’ learning. The main objective of this paper was to assess compliance with indoor air quality and thermal comfort standards in educational buildings, by quantifying HVAC energy implications under natural and mechanical ventilation strategies. For this purpose, an educational building model that has 4 classrooms occupied by students from different age groups was simulated in 11 Mediterranean climate zones, for 4 ventilation strategies, and with 2 building orientations. The results reveal that natural ventilation is effective only in mild Mediterranean climates, with air quality non-compliance ranging from 0 % to 2 % and thermal comfort non-compliance between 2 % and 5 %. As expected, mechanical ventilation always ensures acceptable indoor air quality and thermal comfort. It achieves average HVAC energy savings of 80 % compared to natural ventilation. When considering that students’ CO2 generation rates vary depending on the age, systems with CO2 sensors further reduce HVAC demand (8 %), while maintaining comfort levels. Building orientation was found to have a significant impact for naturally ventilated buildings. South-facing orientations can reduce HVAC energy demand by up to 42 % (1,989 kWh/m2·year), whereas mechanically ventilated buildings show minimal sensitivity to orientation (up to 36 kWh/m2·year). This research will help public authorities of the educational community and architecture and engineering sectors when they are planning, designing and retrofitting educational buildings. Educational building managers will also benefit from this research by being able to optimise building ventilation through the effective management of existing resources.


This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. Maria Maiques gratefully acknowledges the Universitat Politècnica de Catalunya for the financial support of her predoctoral grant FPU-UPC 2023 Complementària, with the collaboration of Banco de Santander. This study was also supported by the Catalan Agency AGAUR under their research group support programme (2021 SGR 00341)


Peer Reviewed


Objectius de Desenvolupament Sostenible::3 - Salut i Benestar


Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat


Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant


Postprint (published version)

Tipus de document

Article

Llengua

Anglès

Publicat per

Elsevier

Documents relacionats

https://www.sciencedirect.com/science/article/pii/S0378778824011927

info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-117366RB-I00/ES/ESTRATEGIAS DE VENTILACION OPTIMIZADAS CONSIDERANDO LA CALIDAD DEL AIRE INTERIOR, EL CONFORT TERMICO Y EL CONSUMO DE ENERGIA EN EDIFICIOS EDUCATIVOS /

Citació recomanada

Aquesta citació s'ha generat automàticament.

Drets

http://creativecommons.org/licenses/by-nc-nd/4.0/

Open Access

Attribution-NonCommercial-NoDerivatives 4.0 International

Aquest element apareix en la col·lecció o col·leccions següent(s)

E-prints [73054]