Contactless acquisition and decoupling of respiratory and cardiac signals using a 122 GHz FMCW radar

dc.contributor
Universitat Politècnica de Catalunya. Doctorat en Teoria del Senyal i Comunicacions
dc.contributor
Universitat Politècnica de Catalunya. Departament de Teoria del Senyal i Comunicacions
dc.contributor
Universitat Politècnica de Catalunya. CommSensLab-UPC - Centre de Recerca en Comunicació i Detecció UPC
dc.contributor
Universitat Politècnica de Catalunya. SPCOM - Processament del Senyal i Comunicacions
dc.contributor.author
Miró Mezquita, Laura
dc.contributor.author
Wu, Ruochen
dc.contributor.author
Aguasca Solé, Alberto
dc.contributor.author
Broquetas Ibars, Antoni
dc.contributor.author
Garcia Garcia, Cosme
dc.contributor.author
Estrada Cuxart, Oriol
dc.contributor.author
Nájar Martón, Montserrat
dc.date.issued
2026-03-12
dc.identifier
Miró, L. [et al.]. Contactless acquisition and decoupling of respiratory and cardiac signals using a 122 GHz FMCW radar. «IEEE journal of biomedical and health informatics», 12 Març 2026, p. 1-14.
dc.identifier
2168-2208
dc.identifier
https://hdl.handle.net/2117/460161
dc.identifier
10.1109/JBHI.2026.3673391
dc.description.abstract
This paper presents a contactless method for the simultaneous monitoring of heart rate (HR) and respiratory rate (RR) using a Frequency Modulated Continuous Wave (FMCW) radar operating at 122.5 GHz. To address the challenges posed by spectral overlap and interference between cardiac and respiratory components, we introduce a signal separation and estimation framework based on Maximum Likelihood Estimation (MLE) combined with an orthogonal projection technique. The approach models the thoracic displacement captured by the radar as the superposition of periodic sources and applies spectral projection to isolate the fundamental frequencies and their harmonics. Theoretical performance is assessed through the derivation of the Cramér-Rao Lower Bound (CRLB) and extensive Monte Carlo simulations under varying SNR and sample size conditions. Experimental validation was conducted on 23 healthy volunteers, each providing two 20 second recordings, using a clinical-grade reference monitor. The method achieves high estimation accuracy, with a mean absolute error of 0.69 bpm for HR and 0.33 bpm for RR. The algorithm is capable of reconstructing the cardiac pulse waveform while preserving key morphological features such as the systolic peak and dicrotic notch. Furthermore, the use of the projection technique further enhanced estimation accuracy under nonphysiological conditions, including both elevated and reduced rates. These findings demonstrate the potential of the proposed method as a reliable tool for contactless monitoring of vital signs and support its future integration into biomedical applications.
dc.description.abstract
This work was supported by the Industrial Doctorates Plan of the Department of Research and Universities of the Generalitat de Catalunya, and is part of the I+D+i project 6-SENSES (PID2022-138648OB-I00) funded by MICIU/AEI/10.13039/501100011033 and ERDF/EU. It is also supported by the Spanish MCIN project PID2020-117303GB-C21, funded by AEI/10.13039/501100011033, and by the China Scholarship Council (CSC) under Grant 202208390068.
dc.description.abstract
Peer Reviewed
dc.description.abstract
Postprint (published version)
dc.format
14 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Institute of Electrical and Electronics Engineers (IEEE)
dc.relation
https://ieeexplore.ieee.org/document/11432837
dc.relation
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2022-138648OB-I00/ES/COMUNICACIONES 6G Y SENSADO PARA REDES INALAMBRICAS DETERMINISTAS/
dc.relation
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-117303GB-C21/ES/TECNICAS RADAR PARA LA OBSERVACION CONTINUA DE LA TIERRA: SISTEMAS Y PROCESADO/
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
Open Access
dc.rights
Attribution 4.0 International
dc.subject
Àrees temàtiques de la UPC::Enginyeria de la telecomunicació::Radiocomunicació i exploració electromagnètica::Radar
dc.subject
Àrees temàtiques de la UPC::Informàtica::Aplicacions de la informàtica::Bioinformàtica
dc.subject
Cardiopulmonary signals
dc.subject
Contactless sensing
dc.subject
Heart rate
dc.subject
Maximum likelihood estimation
dc.subject
mmWave radar
dc.subject
Respiration rate
dc.subject
Vital signs monitoring
dc.title
Contactless acquisition and decoupling of respiratory and cardiac signals using a 122 GHz FMCW radar
dc.type
Article


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

E-prints [72991]