A robust method to measure the fatigue corrosion of shape memory NiTi Wires

dc.contributor
Universitat Politècnica de Catalunya. Departament d'Enginyeria de la Construcció
dc.contributor
Queen's University of Belfast
dc.contributor
Chan, Chi Wai
dc.contributor.author
Llopart Prieto, Jana
dc.date.issued
2015
dc.identifier
https://hdl.handle.net/2117/80063
dc.description.abstract
In the field of NiTi alloys medical implants, it becomes a necessity to have a good understanding of fatigue and corrosion resistance. In the present study, a reliable method was developed in order to assess experimentally the influence of a corrosive environment on the fatigue resistance of 0.5 mm diameter NiTi wires. For this purpose, a corrosion cell was designed with Solidworks CAD tool and later fabricated by using 3D printing technology. Besides, supports for the setup were fabricated through laser cutting of MDF plates. Once the corrosion cell was fabricated, it was coupled with a Bending Rotation Fatigue setup and both parts were fixed over their supports. Experiments were carried out using the resulting test rig, to make sure it was a good tool to assess the simultaneous effect of fatigue and corrosion on material integrity. The tests were performed at slow rotation speed and a certain strain amplitude until the failure of the sample. During their performance, a certain area of the wire was permanently in contact with the electrolyte (3.5% NaCl solution) placed inside the corrosion cell. This experimental procedure allowed getting some preliminary results and validating the functionality and correct design of the test rig. The sample of the first test, performed with the BRF setup and the corrosion cell, broke prematurely in a wrong site. Observations of the sample at different surface points were done with the optical microscope. Existence of corrosion on the material surface was not detected due to the short exposure time of the wire to the corrosive environment. The second test worked properly but due to a lack of time, the sample was characterized before its failure. Optical images collected with the microscope showed a significant difference compared to the previous observations and what seemed to be the beginning of pitting corrosion was detected. Based on the results, design modifications were proposed in order to minimize the test rig probability of failure in future investigation. With this experimental procedure, the main objective was to assure that the designed setup was reliable for its use in further investigation.
dc.description.abstract
Outgoing
dc.format
application/pdf
dc.language
eng
dc.publisher
Universitat Politècnica de Catalunya
dc.publisher
Queen's University Belfast
dc.rights
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights
Open Access
dc.rights
Attribution-NonCommercial-NoDerivs 3.0 Spain
dc.subject
Àrees temàtiques de la UPC::Enginyeria dels materials
dc.subject
Àrees temàtiques de la UPC::Enginyeria biomèdica
dc.subject
Implants, Artificial -- Materials
dc.subject
Nickel-titanium alloys
dc.subject
Wire -- Testing
dc.subject
Implants artificials -- Materials
dc.subject
Níquel-titani -- Aliatges
dc.subject
Filferros -- Proves
dc.title
A robust method to measure the fatigue corrosion of shape memory NiTi Wires
dc.type
Bachelor thesis


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)