Comparing autorefractors for measurement of accommodation

dc.contributor
Universitat Politècnica de Catalunya. Departament d'Òptica i Optometria
dc.contributor
Universitat Politècnica de Catalunya. GREO - Grup de Recerca en Enginyeria Òptica
dc.contributor.author
Aldaba Arévalo, Mikel
dc.contributor.author
Gómez López, Selena
dc.contributor.author
Vilaseca Ricart, Meritxell
dc.contributor.author
Pujol Ramo, Jaume
dc.contributor.author
Arjona Carbonell, Mª Montserrat
dc.date.issued
2015-10-01
dc.identifier
Aldaba , M., Gómez, S., Vilaseca, M., Pujol, J., Arjona, M. Comparing autorefractors for measurement of accommodation. "Optometry and vision science", 01 Octubre 2015, vol. 92, núm. 10, p. 1003-1011.
dc.identifier
1040-5488
dc.identifier
https://hdl.handle.net/2117/81263
dc.identifier
10.1097/OPX.0000000000000685
dc.description.abstract
Purpose To compare the static and dynamic accommodative responses measured with the WAM-5500 and the PowerRef-II autorefractors.; Methods The dynamic and static monocular accommodative responses were measured with the WAM-5500 and the PowerRef-II instruments in 30 pre-presbyopic patients (23.66 [3.19] years). The spherical equivalent was measured at 0.00, 2.50, and 5.00 diopters (D) of accommodative stimulation for the static measurements. The subjective refraction was also determined. Dynamic accommodation was measured for abrupt changes of stimulus vergence of 2.00 D. Mean and peak velocities of accommodation and disaccommodation were evaluated. For the PowerRef-II, dynamic measurements were calculated for sampling frequencies of 5 and 25 Hz.; Results For far distance static results, the differences between subjective and WAM-5500 measurements were 0.07 (+/- 0.21) D (p = 0.093) and those between subjective and PowerRef-II measurements were 0.70 (+/- 0.47) D (p = 0.001). The difference in the response measured with both instruments was 0.08 (+/- 0.32) D (p = 0.194) for 2.50 D and -0.32 (+/- 0.48) D (p = 0.001) for 5.00 D of stimulation. For the dynamic mode, the PowerRef-II at 25 Hz measured faster mean and peak velocities of accommodation and disaccommodation than the WAM-5500, with statistically significant (p < 0.05) differences of 0.68 (+/- 1.01), 0.67 (+/- 0.98), 1.26 (+/- 1.19), and 1.42 (+/- 1.53) D/s, respectively. With a sampling frequency of 5 Hz for the PowerRef-II, these differences, which were statistically significant (p < 0.05), were reduced to 0.52 (+/- 0.90), 0.49 (+/- 0.91), 0.83 (+/- 1.07), and 0.83 (+/- 1.31) D/s, respectively.; Conclusions There is good agreement between subjective refraction and WAM-5500 measurements. In contrast, the PowerRef-II produced more hyperopic results. There were no differences among instruments at 2.50 D of static stimulation; however, differences were found at 5.00 D. In the dynamic measurements, the PowerRef-II measured faster velocities, partly attributed to the difference in the sampling frequency.
dc.description.abstract
Preprint
dc.format
9 p.
dc.format
application/pdf
dc.language
eng
dc.rights
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights
Open Access
dc.subject
Àrees temàtiques de la UPC::Ciències de la visió::Optometria::Acomodació i refracció
dc.subject
Eye--Accommodation and refraction
dc.subject
Presbyopia
dc.subject
accommodation
dc.subject
accommodative response
dc.subject
static
dc.subject
dynamic
dc.subject
WAM-5500
dc.subject
PowerRef-II
dc.subject
ECCENTRIC INFRARED PHOTOREFRACTOR
dc.subject
AGE-RELATED-CHANGES
dc.subject
CLINICAL-EVALUATION
dc.subject
REFRACTIVE ERROR
dc.subject
STATISTICAL-METHODS
dc.subject
GRAND SEIKO
dc.subject
POWERREFRACTOR
dc.subject
DYNAMICS
dc.subject
AGREEMENT
dc.subject
WAM-5500
dc.subject
Ulls -- Acomodació i refracció
dc.subject
Presbícia
dc.title
Comparing autorefractors for measurement of accommodation
dc.type
Article


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)

E-prints [73025]