A methodology for developing Distributed Generation scenarios in urban areas using geographical information systems

Autor/a

Medrano Martorell, Marc

Brouwer, Jack

Carreras-Sospedra, Marc

Rodriguez, Marco A.

Dabdub, Donald

Samuelsen, G. Scott

Data de publicació

2016-03-01T12:23:38Z

2016-03-01T12:23:38Z

2008



Resum

The implementation of Distributed Generation (DG) may lead to increased pollutant emissions that adversely affect air quality. This work presents a systematic methodology to characterise DG installation in urban basins. First, a set of parameters that characterise a DG implementation scenario is described. Second, a general approach using Geographic Information Systems (GIS) data is presented. Third, the methodology is demonstrated by application to the South Coast Air Basin (SoCAB) of California. Results show that realistic scenarios in the SoCAB concentrate DG technologies nearby industrial zones and introduce pollutant mass increments no larger than 0.43% with respect to baseline emissions.


We graciously acknowledge the financial support of the California Energy Commission, sponsor of this work, and the significant leadership and contributions of Marla Mueller, our Contract Manager. M. Carreras and M. Medrano thank the continuing support of the Balsells-Generalitat de Catalunya Fellowship.

Tipus de document

article
publishedVersion

Llengua

Anglès

Matèries i paraules clau

Distributed Generation; scenarios; CHP

Publicat per

Inderscience

Documents relacionats

Reproducció del document publicat a https://doi.org/10.1504/IJETP.2008.019958

International Journal of Energy Technology and Policy, 2008, vol. 6, núm. 4, p. 413-434