Industrial wastewater treatment plants must operate properly during the transient-state conditions often found in the industrial production. This study presents the performance of simultaneous partial nitritation and o-cresol biodegradation in a continuous aerobic granular reactor under sequentially alternating pollutant (SAP) scenarios. Three SAP scenarios were imposed during the operation of the granular reactor. In each one, a secondary recalcitrant compound (either p-nitrophenol (PNP), phenol or 2-chlorophenol (2CP)) were added for a short period of time to the regular influent containing only ammonium and o-cresol. Partial nitritation and o-cresol biodegradation were not inhibited by the presence of PNP or phenol and both compounds were fully biodegraded. On the contrary, the presence of 2CP strongly inhibited both processes within 2 days. However, the reactor was recovered in a few days. These findings demonstrate that treatment of complex industrial wastewaters with variable influent composition is feasible in a continuous aerobic granular reactor.
Anglès
Partial nitrification; Aerobic granules; P-nitrophenol; Phenol; 2-Chlorophenol
Ministerio de Economía y Competitividad CTQ2011-24745/PPQ
Bioresource technology ; Vol. 161 (June 2014), p. 354-361
open access
Aquest material està protegit per drets d'autor i/o drets afins. Podeu utilitzar aquest material en funció del que permet la legislació de drets d'autor i drets afins d'aplicació al vostre cas. Per a d'altres usos heu d'obtenir permís del(s) titular(s) de drets.
https://rightsstatements.org/vocab/InC/1.0/