Fault detection and isolation of a real PEM fuel cell using interval LPV observers

Otros/as autores/as

Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial

Universitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control

Fecha de publicación

2012

Resumen

The purpose of this paper is to design a Fault Detection and Isolation (FDI) system based on interval LPV observers with application to a real fuel cell. The interval LPV observer is used to generate an adaptive threshold to enhance the robustness of the fault detection test. Real field data and system identification techniques are used to identify the nominal model as well as its uncertainty. Since fuel cells are highly non-linear systems when operating in their whole range of operation, a LPV model is used. Finally, fault isolation is based on an algorithm that uses the residual fault sensitivity. Several fault scenarios are used to show the performance of the proposed approach.


Peer Reviewed


Postprint (published version)

Tipo de documento

Conference report

Lengua

Inglés

Publicado por

IFAC

Documentos relacionados

http://cataleg.upc.edu/record=b1419598~S1*cat

Citación recomendada

Esta citación se ha generado automáticamente.

Derechos

Restricted access - author's decision

Este ítem aparece en la(s) siguiente(s) colección(ones)

E-prints [73026]