Método de doble punzonamiento de tracción indirecta para concreto reforzado con fibra: Ensayo Barcelona

Altres autors/es

Universitat Politècnica de Catalunya. Departament d'Enginyeria de la Construcció

Universitat Politècnica de Catalunya. TE - Tecnologia d'Estructures

Data de publicació

2013-12-10

Resum

The present work describes the results of an experimental investigation on the performances of concrete specimens reinforced with steel fibers using the double punch test (DPT). The DPT is an indirect tensile test based on the configuration of double-punch test, named, Barcelona test that was developed for the systematic control of fiber reinforced concrete. DPT can be carried out by testing 150 × 150 mm concrete cylinders subjected to double punching test. Previous experimental results have showed that DPT gives significantly lower variability compared to other test methods. In the test performed, indirect tensile strength and fracture toughness result obtained by DPT were compared using molded cylinder and core concrete specimens.


Postprint (published version)

Tipus de document

Book

Llengua

Castellà

Publicat per

Universidad Nacional Autónoma de México

Documents relacionats

http://aplicaciones.iingen.unam.mx/ConsultasSPII/DetallePublicacion.aspx?id=4957

Citació recomanada

Aquesta citació s'ha generat automàticament.

Drets

Restricted access - publisher's policy

Aquest element apareix en la col·lecció o col·leccions següent(s)

E-prints [72985]