Influence of ECAP process on mechanical, corrosion and bacterial properties of Zn-2Ag alloy for wound closure devices

Altres autors/es

Universitat Politècnica de Catalunya. Departament de Ciència i Enginyeria de Materials

Universitat Politècnica de Catalunya. Departament d'Enginyeria Química

Universitat Politècnica de Catalunya. CIEFMA-PROCOMAME - Disseny Microestructural i Fabricació Avançada de Materials

Universitat Politècnica de Catalunya. BBT - Grup de recerca en Biomaterials, Biomecànica i Enginyeria de Teixits

Universitat Politècnica de Catalunya. R2EM - Resource Recovery and Environmental Management

Politecnico di Milano

Institut de Bioenginyeria de Catalunya

Data de publicació

2023-04-01

Resum

Actual polymeric wound closure devices are not optimal for load-bearing applications due to the low mechanical properties and the risk of inflammation and bacterial infection mainly produced by multifilament and braided configurations. Biodegradable metallic Zn alloys are promising materials candidates; however, mechanical performance, corrosion behaviour, and biological response should be controlled in order to inhibit the risk of inflammation and bacterial infection. To this end, a Zn-2Ag (2 wt% Ag) alloy was processed by ECAP to evaluate the concurrent combined effect of grain refinement and Ag alloying on biodegradation and antibacterial activity. Two ECAP cycles were successfully applied to a Zn-2Ag alloy obtaining a homogeneous ultra-fine-grained structure in which nanoindentation maps suggested isotropic mechanical properties. Lower UTS and YS with higher elongation was reported after ECAP with similar corrosion rates as before processing. ECAP processed samples showed a homogeneous Ag+ release below the minimum inhibitory concentration for S. Aureus and no antibacterial effect was observed by diffusion. As expected, the presence of Ag in Zn-Ag alloys reduced bacterial attachment. Nevertheless, ECAP processed Zn-2Ag provided an excellent antibacterial activity after 3 h probably caused by the uniformly degraded and thus, non– stable, surface observed after bacterial adhesion.


Peer Reviewed


Postprint (published version)

Tipus de document

Article

Llengua

Anglès

Publicat per

Elsevier

Documents relacionats

https://www.sciencedirect.com/science/article/pii/S0264127523002320

Citació recomanada

Aquesta citació s'ha generat automàticament.

Drets

http://creativecommons.org/licenses/by-nc-nd/4.0/

Open Access

Attribution-NonCommercial-NoDerivatives 4.0 International

Aquest element apareix en la col·lecció o col·leccions següent(s)

E-prints [72986]