High-throughput wide dynamic range procedure for the simultaneous quantification of nicotine and cotinine in multiple biological matrices using hydrophilic interaction liquid chromatography-tandem mass spectrometry

dc.contributor.author
Pérez Ortuño, Raúl
dc.contributor.author
Martínez Sánchez, José M.
dc.contributor.author
Fernández Muñoz, Esteve
dc.contributor.author
Pascual, José Antonio
dc.date.issued
2020-11-12T11:34:05Z
dc.date.issued
2020-11-12T11:34:05Z
dc.date.issued
2015-09-05
dc.date.issued
2020-11-12T11:34:06Z
dc.identifier
1618-2642
dc.identifier
https://hdl.handle.net/2445/171983
dc.identifier
656863
dc.identifier
26342312
dc.description.abstract
A straightforward, high-throughput method was developed and fully validated for the simultaneous determination of the specific tobacco biomarkers nicotine and its main metabolite cotinine in a wide dynamic range and supporting the most common human biological matrices (urine, oral fluid and hair). Sample preparation was performed inside the very HPLC injection vials by pipetting 0.5 mL of the liquid samples, deuterated internal standards in alkaline solution and dichloromethane as extraction solvent. Solid samples (i.e. around 10 mg hair) were first submitted to alkaline digestion in the HPLC vials and processed accordingly. The organic phase (reached through the upper aqueous layer) was directly injected without further treatment. Instrumental analysis was performed using hydrophilic interaction (HILIC) ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Total chromatographic time was 2 min. The method covers a wide dynamic range making it fit-for-purpose for the analysis of samples covering entire populations, irrespective of the level of exposure or tobacco use. Calibration curves (r 2 > 0.995) covered the range 1-2000 ng/mL (or 0.05-100 ng/mg hair) for nicotine and 0.1-2000 ng/mL (or 0.005-100 ng/mg hair) for cotinine. Within-run and between-run precision and accuracy were typically below 10 %, and always below 20 % at the lower limit of quantification. The method was successfully applied to the analysis of samples from different projects involving multiple matrices.
dc.format
11 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Springer Verlag
dc.relation
Versió postprint del document publicat a: https://doi.org/10.1007/s00216-015-8993-7
dc.relation
Analytical and Bioanalytical Chemistry, 2015, vol. 407, p. 8463-8473
dc.relation
https://doi.org/10.1007/s00216-015-8993-7
dc.rights
(c) Springer Verlag, 2015
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Ciències Clíniques)
dc.subject
Espectrometria de masses
dc.subject
Nicotina
dc.subject
Marcadors bioquímics
dc.subject
Mass spectrometry
dc.subject
Nicotine
dc.subject
Biochemical markers
dc.title
High-throughput wide dynamic range procedure for the simultaneous quantification of nicotine and cotinine in multiple biological matrices using hydrophilic interaction liquid chromatography-tandem mass spectrometry
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.