Marginal Bone Loss in Implants with External Connection versus Internal Conical Connection Prior to Prosthetic Loading. A Randomized Clinical Study

dc.contributor.author
Palacios Garzón, Natalia
dc.contributor.author
Ayuso Montero, Raúl
dc.contributor.author
Jané Salas, Enric
dc.contributor.author
Anglada Cantarell, José María
dc.contributor.author
López López, José, 1958-
dc.date.issued
2021-02-10T07:43:29Z
dc.date.issued
2021-02-10T07:43:29Z
dc.date.issued
2020-11-01
dc.date.issued
2021-02-08T10:17:10Z
dc.identifier
https://hdl.handle.net/2445/173802
dc.description.abstract
Introduction: The prosthetic connection of implants has been related to the loss of marginal bone. The aim of this study was to evaluate bone loss around external connection (EC) and internal conical connection (ICC) implants prior to prosthetic loading. Material and methods: A randomized clinical trial (RCT) was carried out, with a sample size of 93 implants (31 EC and 62 ICC) placed in 27 patients. Radiological controls were performed and stability was measured by resonance frequency analysis (RFA) on the day of placement, at 1 month and at 4 months after the placement. Results: Bone loss in EC implants was not statistically different than in ICC implants between the time of placement (T0) and the subsequent month (T1): (EC = 0.18 mm and ICC = 0.17 mm). Between one month (T1) and four months (T2): (EC = 0.39 mm and ICC = 0.19 mm) this difference was highly significant (p = 0.00). Bone loss between T0 and T2 was significantly lower in the ICC (EC = 0.57 mm and ICC = 0.36 mm), (p = 0.01). The overall success rate of the implants was 97.8%. The stability of the implants increased from 70.69 (T0) to 73.91 (T1) and 75.32 (T2). Conclusions: ICC showed less bone loss up to the time of prosthesis placement. Such bone loss did not have a significant impact on bone stability. Long term RCTs are needed to demonstrate whether this bone loss, which is more pronounced at the beginning in EC, tends to stabilize and equate to ICC.
dc.format
17 p.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI
dc.relation
Reproducció del document publicat a: https://doi.org/10.3390/coatings10111044
dc.relation
Coatings, 2020, vol. 10, num. 11
dc.relation
https://doi.org/10.3390/coatings10111044
dc.rights
cc by (c) Palacios Garzón et al., 2020
dc.rights
http://creativecommons.org/licenses/by/3.0/es/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Odontoestomatologia)
dc.subject
Implants dentals
dc.subject
Prostodòncia
dc.subject
Dental implants
dc.subject
Prosthodontics
dc.title
Marginal Bone Loss in Implants with External Connection versus Internal Conical Connection Prior to Prosthetic Loading. A Randomized Clinical Study
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.