In Vitro Characterization of an Anodized Surface of a Dental Implant Collar and Dental Abutment on Peri-Implant Cellular Response

dc.contributor.author
Traver Méndez, Valeria
dc.contributor.author
Camps Font, Octavi
dc.contributor.author
Ventura Pujol, Francesc
dc.contributor.author
Nicolau Sansó, Miquel Àngel
dc.contributor.author
Subirà Pifarré, Carles
dc.contributor.author
Barbosa de Figueiredo, Rui Pedro
dc.contributor.author
Valmaseda Castellón, Eduardo
dc.date.issued
2023-12-19T15:05:53Z
dc.date.issued
2023-12-19T15:05:53Z
dc.date.issued
2023-09-01
dc.date.issued
2023-12-19T15:05:53Z
dc.identifier
1996-1944
dc.identifier
https://hdl.handle.net/2445/204926
dc.identifier
740281
dc.identifier
37687706
dc.description.abstract
The purpose of this paper was to determine the effect of anodization on the in vitro proliferation and adhesion of immortalized human keratinocytes (HaCats) and mouse bone marrow-derived mesenchymal stem cells (BM-MSCs) in Titanium Grade 23 (Ti6Al4V ELI) discs and to describe the surface topography, roughness, and composition of dental implants (body and collar) and abutments submitted to an area-specific anodization process. HaCat cells and BM-MSCs were seeded onto discs with three different surface treatments: machined, area-specific anodization for abutments, and area-specific anodization for implant collars. Cell proliferation was assessed using a resazurin-based fluorescent dye on days 1, 3, and 7, while cell adhesion was examined using scanning electron microscopy (SEM). Surface topography, roughness, and composition were evaluated for six implant bodies with an anodized rough surface, six anodized implant smooth collars, and six anodized prosthetic abutments. Both HaCats and BM-MSCs showed increased viability over time (p < 0.001 ) with no statistically significant differences among the different surfaces (p = 0.447 HaCats and p = 0.631 BM-MSCs). SEM analysis revealed an enhanced presence and adhesion of HaCat cells on the anodized surface for the implant collars and an increased adhesion of BM-MSCs on both the anodized and machined surface abutments. The topography characteristics of the treated implants and abutments varied depending on the specific implant region. Chemical analysis confirmed the presence of oxygen, calcium, phosphorus, and sodium on the anodized surfaces. The area-specific anodization process can be utilized to create variable topography, increase the specific surface area, and introduce oxygen, calcium, phosphorus, and sodium to dental implants and abutments. While BM-MSCs and HaCat cells showed similar adhesion and proliferation on anodized and machined surfaces, a positive interaction between anodized Ti6Al4V ELI surfaces and these two cell lines present in the peri-implant mucosa was observed. Due to the limitations of the present study, further research is necessary to confirm these findings.
dc.format
13 p.
dc.format
application/pdf
dc.format
application/pdf
dc.language
eng
dc.publisher
MDPI
dc.relation
Reproducció del document publicat a: https://doi.org/10.3390/ma16176012
dc.relation
Materials, 2023, vol. 16, num.17
dc.relation
https://doi.org/10.3390/ma16176012
dc.rights
cc-by (c) Traver Méndez, Valeria et al., 2023
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Odontoestomatologia)
dc.subject
Pròtesis dentals
dc.subject
Immunologia
dc.subject
Dental prosthesis
dc.subject
Immunology
dc.title
In Vitro Characterization of an Anodized Surface of a Dental Implant Collar and Dental Abutment on Peri-Implant Cellular Response
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.