dc.contributor.author
Medina-Pérez, Noemí I.
dc.contributor.author
Santos Vicente, Francisco Javier
dc.contributor.author
Berdalet, Elisa
dc.contributor.author
Moyano Morcillo, Encarnación
dc.date.issued
2024-12-11T18:03:00Z
dc.date.issued
2024-12-11T18:03:00Z
dc.date.issued
2023-02-06
dc.date.issued
2024-12-11T18:03:00Z
dc.identifier
https://hdl.handle.net/2445/217045
dc.description.abstract
Analogues of palytoxin (PLTX), one of the most potent marine biotoxins, are produced by some species of the marine dinoflagellates of the genus Ostreopsis. The proliferation of these species in different coastal zones represents a potential threat of seafood poisoning in humans because the produced toxins can be transferred through the marine food webs. Thus, the determination of the concentration of PLTX analogues (ovatoxins- OVTXs, ostreocins-OSTs and isobaric PLTX) in different matrices (seawater, marine fauna, etc.) is necessary to protect human health. This study is addressed to overcome some of the challenges that the chemical complexity of these molecules poses to their quantification by ultra-high-performance liquid chromatography high-resolution mass spectrometry-based techniques (UHPLC-HRMS). In particular, the mass spectrum of the palytoxin analogues shows the presence of a large number of ions (including mono- and multiply-charged ions) whose nature, relative abundances and behavior can lead to quantitation errors if the correct ions are not selected. In this work, the variability of the PLTX and OVTXs profiles under different instrument conditions, including the use of diverse electrospray generation sources and different quantitation methods, is studied. Moreover, the extraction protocol in seawater containing Ostreopsis sp. ovata cells is also evaluated. The use of a heated electrospray operating at 350 °C and a quantitative method including ions from different multiplycharged species provides a more robust and reliable method overcoming the problems due to the variability in the toxin's mass spectrum profile. A single MeOH:H2O (80:20, v/v) extraction is proposed as the best and reliable procedure. The overall method proposed was applied to quantify OVTXs (-a to -g) and iso-PLTX along the 2019 Ostreopsis cf. ovata bloom. The cells contained a total toxin concentration up to 20.39 pg cell-1.
dc.format
application/pdf
dc.publisher
Royal Society of Chemistry
dc.relation
Reproducció del document publicat a: https://doi.org/10.1039/d2ay02019j
dc.relation
Analytical Methods, 2023, vol. 15, p. 1355-1364
dc.relation
https://doi.org/10.1039/d2ay02019j
dc.rights
cc-by-nc (c) Medina-Pérez, N. I. et al., 2023
dc.rights
http://creativecommons.org/licenses/by-nc/3.0/es/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Cromatografia de líquids d'alta resolució
dc.subject
Vasoconstrictors
dc.subject
High performance liquid chromatography
dc.subject
Vasoconstrictors
dc.title
Multiply charged ions profile in the UHPLC-HRMS analysis of palytoxin analogues from Ostreopsis cf. ovata blooms
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion