dc.contributor.author
Liendo, F.
dc.contributor.author
Bryan Pichún, B.
dc.contributor.author
Paz de la Vega, A.
dc.contributor.author
Penagos, J.
dc.contributor.author
Serrano i Plana, Núria
dc.contributor.author
Díaz Cruz, José Manuel
dc.contributor.author
Pizarro, J.
dc.contributor.author
Segura, R.
dc.contributor.author
Aguirre, M.J.
dc.date.issued
2025-01-30T18:01:38Z
dc.date.issued
2025-01-30T18:01:38Z
dc.date.issued
2024-09-09
dc.date.issued
2025-01-30T18:01:39Z
dc.identifier
https://hdl.handle.net/2445/218270
dc.description.abstract
In this study, a new and simple glassy carbon electrode modified with carbon nanohorns (SWCNH/GCE) was used for the determination of Cr(VI) in aqueous matrices via adsorptive cathodic stripping voltammetry (AdCSV). The modified electrode was characterized via field emission scanning electron microscopy and cyclic voltammetry, which revealed a homogeneous distribution of spherical agglomerates of SWCNH on the electrode surface. The modification increased the electrochemically active area from 0.10 cm2 ± 0.01 (GCE) to 0.16 cm2 ± 0.01 (SWCNH/GCE). The optimized analytical conditions were as follows: a supporting electrolyte (0.15 mol L−1 HCl), an accumulation potential of 0.8 V versus Ag/AgCl, and an accumulation time of 240 s. Validation of the analytical methodology was performed, obtaining a linear range between 20 and 100 µg L−1, a limit of detection of 3.5 µg L−1, and a limit of quantification of 11.6 µg L−1 with good accuracy and precision. The method was applied to the analysis of spiked tap water samples, and the results were compared using a flame atomic absorption spectrophotometer (FAAS) with no significant statistical differences.
dc.format
application/pdf
dc.relation
Reproducció del document publicat a: https://doi.org/https://doi.org/10.3390/nano14171465
dc.relation
Nanomaterials, 2024, vol. 14, num.17
dc.relation
https://doi.org/https://doi.org/10.3390/nano14171465
dc.rights
cc-by (c) Liendo, F. et al., 2024
dc.rights
http://creativecommons.org/licenses/by/4.0/
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Electroquímica
dc.subject
Electrochemistry
dc.title
Electrochemical sensor based on glassy carbon electrode modified with carbon nanohorns (SWCNH) for determination of Cr(VI) via adsorptive cathodic stripping voltammetry (AdCSV) in tap water
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion