Determination of chromium(VI) with screen-printed ex-situ bismuth film electrodes by adsorptive stripping voltammetry

dc.contributor.author
Triviño, Juan José
dc.contributor.author
Esteban i Cortada, Miquel
dc.contributor.author
Díaz Cruz, José Manuel
dc.contributor.author
Serrano i Plana, Núria
dc.contributor.author
Alvarez-Lueje, Alejandro
dc.contributor.author
Arancibia, Verónica
dc.date.issued
2025-06-13T16:44:33Z
dc.date.issued
2025-12-31T06:10:41Z
dc.date.issued
2025-01-01
dc.date.issued
2025-06-13T16:44:33Z
dc.identifier
1040-0397
dc.identifier
https://hdl.handle.net/2445/221533
dc.identifier
755193
dc.description.abstract
This work presents a fast and sensitive method, with an ex–situ bismuth film screen-printed carbon electrode (ex–situ Bi–SPCE), for the determination of Cr(VI) through adsorptive stripping voltammetry (AdSV) using Pyrogallol Red (PGR) ascomplexing agent. The method is based on the oxidation of PGR by Cr(VI) and posterior complexation with Cr(III). To obtaina sensitive and selective method, the effects of various parameters such as pH, ligand concentration of PGR (CPGR),accumulation potential, and accumulation time (Eacc, tacc) were optimized. The optimal conditions using Bi–SPCE preparedex–situ were pH 4.5 (0.01 molL<sup>-1</sup> acetic acid/acetate buffer), CPGR: 2.6 μmolL<sup>-1</sup>, Eacc: - 0.70 V and tacc: 60 s. Peak current isproportional to Cr(VI) concentration over the range 0.23–12.0 μgL<sup>-1</sup>, with a 3σ detection limit of 0.97 μgL<sup>-1</sup>. The method wasvalidated by determining Cr(VI) in tap water spiked with Cr(VI) and Cr(III).
dc.format
10 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Wiley-VCH
dc.relation
Versió postprint del document publicat a: https://doi.org/https://doi.org/10.1002/elan.202400218
dc.relation
Electroanalysis, 2025, vol. 37, p. 1-10
dc.relation
https://doi.org/https://doi.org/10.1002/elan.202400218
dc.rights
(c) Wiley-VCH, 2025
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject
Adsorció
dc.subject
Voltametria
dc.subject
Crom
dc.subject
Adsorption
dc.subject
Voltammetry
dc.subject
Chromium
dc.title
Determination of chromium(VI) with screen-printed ex-situ bismuth film electrodes by adsorptive stripping voltammetry
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)