dc.description.abstract
Head space gas chromatography with flame-ionization detection (HS-GC-FID), ancl purge and trap gas chromatography-mass spectrometry (P&T-GC-MS) have been used to determine methyl-tert-butyl ether (MTBE) and benzene, toluene, and the ylenes (BTEX) in groundwater. In the work discussed in this paper measures of quality, e.g. recovery (94-111%), precision (4.6 - 12.2%), limits of detection (0.3 - 5.7 I~g L 1 for HS and 0.001 I~g L 1 for PT), and robust-ness, for both methods were compared. In addition, for purposes of comparison, groundwater samples from areas suffering from odor problems because of fuel spillage and tank leakage were analyzed by use of both techniques. For high concentration levels there was good correlation between results from both methods.
dc.format
application/pdf
dc.format
application/pdf
dc.publisher
Springer Verlag
dc.relation
Chromatographia, 2002, vol. 56, num. 11-12, p. 739-744
dc.rights
(c) Springer Verlag, 2002
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Mineralogia, Petrologia i Geologia Aplicada)
dc.subject
Hidrologia d'aigües subterrànies
dc.subject
Groundwater hydrology
dc.title
Cross-validation of methods used for analysis of MTBE and other gasoline components in groundwater.
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/acceptedVersion