Force Spectroscopy with Dual-Trap Optical Tweezers: Molecular Stiffness Measurements and Coupled Fluctuations Analysis

dc.contributor.author
Ribezzi-Crivellari, M.
dc.contributor.author
Ritort Farran, Fèlix
dc.date.issued
2014-04-08T10:16:55Z
dc.date.issued
2014-04-08T10:16:55Z
dc.date.issued
2012-11-07
dc.date.issued
2014-04-08T10:16:55Z
dc.identifier
0006-3495
dc.identifier
https://hdl.handle.net/2445/53339
dc.identifier
625942
dc.identifier
23199920
dc.description.abstract
ABSTRACT Dual-trap optical tweezers are often used in high-resolution measurements in single-molecule biophysics. Such measurements can be hindered by the presence of extraneous noise sources, the most prominent of which is the coupling of fluctuations along different spatial directions, which may affect any optical tweezers setup. In this article, we analyze, both from the theoretical and the experimental points of view, the most common source for these couplings in dual-trap optical-tweezers setups: the misalignment of traps and tether. We give criteria to distinguish different kinds of misalignment, to estimate their quantitative relevance and to include them in the data analysis. The experimental data is obtained in a, to our knowledge, novel dual-trap optical-tweezers setup that directly measures forces. In the case in which misalignment is negligible, we provide a method to measure the stiffness of traps and tether based on variance analysis. This method can be seen as a calibration technique valid beyond the linear trap region. Our analysis is then employed to measure the persistence length of dsDNA tethers of three different lengths spanning two orders of magnitude. The effective persistence length of such tethers is shown to decrease with the contour length, in accordance with previous studies.
dc.format
10 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Biophysical Society
dc.relation
Reproducció del document publicat a: http://dx.doi.org/10.1016/j.bpj.2012.09.022
dc.relation
Biophysical Journal, 2012, vol. 103, num. 9, p. 1919-1928
dc.relation
http://dx.doi.org/10.1016/j.bpj.2012.09.022
dc.rights
(c) Biophysical Society, 2012
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Física de la Matèria Condensada)
dc.subject
Biofísica
dc.subject
ADN
dc.subject
Polímers
dc.subject
Elasticitat
dc.subject
Aparells i instruments científics
dc.subject
Molècules
dc.subject
Espectroscòpia
dc.subject
Biophysics
dc.subject
DNA
dc.subject
Polymers
dc.subject
Elasticity
dc.subject
Scientific apparatus and instruments
dc.subject
Molecules
dc.subject
Spectrum analysis
dc.title
Force Spectroscopy with Dual-Trap Optical Tweezers: Molecular Stiffness Measurements and Coupled Fluctuations Analysis
dc.type
info:eu-repo/semantics/article
dc.type
info:eu-repo/semantics/publishedVersion


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)