Detection of isothermally amplified ostreid herpesvirus 1 DNA in Pacific oyster (Crassostrea gigas) using a miniaturised electrochemical biosensor

dc.contributor.author
Toldrà, Anna
dc.contributor.author
Furones, M. Dolors
dc.contributor.author
O'Sullivan, Ciara K.
dc.contributor.author
Campàs, Mònica
dc.contributor.other
Producció Animal
dc.date.accessioned
2025-10-22T11:29:51Z
dc.date.available
2025-10-22T11:29:51Z
dc.date.issued
2019-09-02
dc.identifier.citation
Toldrà, Anna, M. Dolors Furones, Ciara K. O'Sullivan, and Mònica Campàs. 2020. "Detection Of Isothermally Amplified Ostreid Herpesvirus 1 DNA In Pacific Oyster (Crassostrea Gigas) Using A Miniaturised Electrochemical Biosensor". Talanta 207: 120308. Elsevier BV. doi:10.1016/j.talanta.2019.120308.
dc.identifier.issn
0039-9140
dc.identifier.uri
https://hdl.handle.net/20.500.12327/493
dc.description.abstract
Given the threat that ostreid herpesvirus 1 (OsHV-1) poses to shellfish aquaculture, the need for rapid, user-friendly and cost-effective methods to detect this marine pathogen and minimise its impact is evident. In this work, an electrochemical biosensor for the detection of OsHV-1 based on isothermal recombinase polymerase amplification (RPA) was developed. The system was first tested and optimised on maleimide microtitre plates as a proof-of-concept, before being implemented on miniaturised gold electrodes. Amperometric detection of the isothermally amplified product was achieved through a sandwich hybridisation assay with an immobilised thiolated capture probe and a horseradish peroxidase (HRP)-labelled reporter probe. Calibration curves were constructed using PCR-amplified OsHV-1 DNA, achieving a limit of detection of 207 OsHV-1 target copies. The biosensor was applied to the analysis of 16 oyster samples from an infectivity experiment, and results were compared with those obtained by qPCR analysis, showing a strong degree of correlation (r = 0.988). The simplicity, rapidity, cost-effectiveness and potential for in-situ testing with the developed biosensor provide a valuable tool for the detection of OsHV-1 in aquaculture facilities, improving their management.
dc.format.extent
24
dc.language.iso
eng
dc.publisher
Elsevier
dc.relation.ispartof
Talanta
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.title
Detection of isothermally amplified ostreid herpesvirus 1 DNA in Pacific oyster (Crassostrea gigas) using a miniaturised electrochemical biosensor
dc.type
info:eu-repo/semantics/article
dc.subject.udc
639
dc.description.version
info:eu-repo/semantics/acceptedVersion
dc.relation.projectID
EC/H2020/678589/EU/Preventing and mitigating farmed bivalve diseases/VIVALDI
dc.identifier.doi
https://doi.org/10.1016/j.talanta.2019.120308
dc.rights.accessLevel
info:eu-repo/semantics/openAccess
dc.contributor.group
Aigües Marines i Continentals
dc.contributor.group
Aqüicultura


Fitxers en aquest element

FitxersGrandàriaFormatVisualització

No hi ha fitxers associats a aquest element.

Aquest element apareix en la col·lecció o col·leccions següent(s)