Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography

dc.contributor.author
Sala Puigdollers, Anna
dc.contributor.author
Figueras Roca, Marc
dc.contributor.author
Hereu, Mireia
dc.contributor.author
Hernandez, Teresa
dc.contributor.author
Morato, Montse
dc.contributor.author
Adán Civera, Alfredo
dc.contributor.author
Zarranz Ventura, Javier
dc.date.issued
2020-02-03T11:52:22Z
dc.date.issued
2020-02-03T11:52:22Z
dc.date.issued
2018-07-26
dc.date.issued
2020-02-03T11:52:22Z
dc.identifier
1932-6203
dc.identifier
https://hdl.handle.net/2445/149223
dc.identifier
687863
dc.identifier
30048478
dc.description.abstract
Purpose To evaluate the repeatability and reproducibility of retinal and choroidal thickness measured with Swept source Optical Coherence Tomography (SS-OCT) in eyes with Diabetic Macular Edema (DME). Methods 42 DME eyes were imaged using SS-OCT standard Macular scanning protocols. Retinal and choroidal thickness were measured in the Total macular circle (TMC) and foveal central subfield (FCS) using device-integrated specific software. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were determined as a measure of repeatability and relative reliability within graders. Reproducibility was assessed using Bland-Altman plots and 95% limits of agreement (LoA) were determined as a measure of interobserver variability. Results Intragrader CR of retinal and choroidal thickness were 8.37 and 12.20 microns for TMC and 22.24 and 32.40 microns for FCS, and intergrader 95% LoA were 7.37 +/- 8.69 and -27.2 +/- 27.71 microns for TMC and -34.21 +/- 41.93 and -30.46 +/- 24.84 for FCS, respectively. Retinal and choroidal thickness showed very good intraobserver reliability for both TMC and FCS (ICC 0.99, LoA 0.98 +/- 0.99 in all cases). Intraobserver and interobserver variability for retinal and choroidal thickness was not significantly different for TMC (p = 0.98 and p = 0.90, p = 0.98 and p = 0.91) or FCS (p = 0.97 and p = 0.85, p = 0.78 and p = 0.73), respectively. Conclusions Retinal and choroidal thickness in DME eyes can be quantified with good reliability, repeatability and reproducibility using new OCT devices that incorporate swept source technology. The technical advantages of this technology may provide new insights in the understanding of the choroidal changes related with DME.
dc.format
12 p.
dc.format
application/pdf
dc.language
eng
dc.publisher
Public Library of Science (PLoS)
dc.relation
Reproducció del document publicat a: https://doi.org/10.1371/journal.pone.0200819
dc.relation
PLoS One, 2018, vol. 13, num. 7, p. e0200819
dc.relation
https://doi.org/10.1371/journal.pone.0200819
dc.rights
cc-by (c) Sala Puigdollers, Anna et al., 2018
dc.rights
http://creativecommons.org/licenses/by/3.0/es
dc.rights
info:eu-repo/semantics/openAccess
dc.source
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject
Retinopatia diabètica
dc.subject
Tomografia de coherència òptica
dc.subject
Diabetic retinopathy
dc.subject
Optical coherence tomography
dc.title
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography
dc.type
info:eu-repo/semantics/article